Operation
In the control soware, under the settings tab, the camera
option must be checked to adapt the acceleration and travel to
the weight on the processing head.
Notice
When the camera is removed, the hook can be
removed to return the speed and travel distance
to maximum.
7.9.6
Temperature sensor
7.9.6.1 Temperature sensor
The temperature sensors ensure reliable temperature monitoring of the interior of the machine and are available as
additional option.
If a preset temperature value is exceeded, an acoustic alarm continuously sounds to warn the operator of abnormal
temperature trends during processing.
Warning
Fire hazard
The acoustic alarm upon startup of the machine indicates that the sensors are operating properly.
However, the sensors do not guarantee fire prevention.
–
The unit must not operate unattended despite the integrated temperature sensors.
–
If the acoustic alarm does not sound when the machine is switched on, check the functionality of the
sensors.
–
In case of questions, contact our experienced Technical Support in your local area.
TEMPERATURE SENSOR ALARM ACKNOWLEDGEMENT
Press any key on the keypad to acknowledge the alarm.
Notice
The signal tone sounds again and again until the temperature returns to normal. Alternatively, switch off
the laser system and check the temperature sensors.