8
EN
multiple socket outlet PV4-MID-PS
Operation
Connecting the multiple socket outlet
1. Insert the device plug of the device
PV4-MID-PS
into a
properly secured socket.
ð
The device is now connected.
ð
In order to use the device, the residual current device must
be switched on.
Using the residual current device (RCD)
If you switch on the bipolar residual current device RCD (7), it
can prevent an electric shock. The colour indicator shows the
switching state (red=ON, green=OFF).
1. Open the sealing cap (1).
2. Set the flip switch of the residual current device RCD (7)
to 'red'.
ð
The residual current protection is activated.
3. Set the flip switch of the residual current device RCD (7)
to 'green'.
ð
The residual current protection is deactivated.
kW
h
kW
h
2
3
1
7
Securing the multiple socket outlet by means of seals
You can protect the multiple socket outlet against unauthorised
access by means of one or more seals (12). Securing the
multiple socket outlet can be realised whether a plug has been
inserted into the safety socket (5) or not.
One seal (12) per plug or safety socket (5) will be required. For
assembly of the seals (12) please proceed as follows:
1. Open the cover of a safety socket (10).
2. Pull the open end of the seal cable (14) out of the
anchoring at the end of the seal (12).
3. Then, pull the open end of the seal cable (14) through an
eyelet (9) of a safety socket (5).
4. If there is a plug inserted in the safety socket (5), wind the
seal cable around the safety plug one time.
5. Then, pull the open end of the seal cable (14) through the
opposing eyelet (9) of the safety socket (5).
6. Pull the open end of the seal cable (14) through the
anchoring for the seal (13) and tighten the seal cable.
7. Check whether the safety socket (5) can be opened.
ð
If this is the case, tighten the seal cable or repeat
steps 1–7.
ð
If you cannot open the safety socket (5) any longer or if the
plug cannot be pulled out, the safety socket (5) is secured.