multiple socket outlet PV4-MID-PS

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

To make the device easier to transport, it is fitted with a carry
handle.

Before

 transporting the device, observe the following:

Always close the sealing cap of the MID-compliant energy
meter before transporting the device.

Storage

When the device is not being used, observe the following
storage conditions:

dry and protected from frost and heat

protected from dust and direct sunlight

with a cover to protect it from invasive dust, if necessary

The storage temperature is the same as the range given in
the Technical data chapter.

Start-up

Warning of electrical voltage

Work on the electrical components must only be
carried out by a qualified electrician!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Note

Prior to initial start-up, have all pre-assembled
connection screws inside the housing checked and, if
necessary, retightened by a qualified electrician.

Do not create tripping hazards when laying the power
cable or other electric cables when positioning the device.
If necessary, use cable bridges.

Make sure that extension cables are unrolled completely.

Do not cover the device.

Do not place any further objects on the device.

Insert the CEE plug into a properly secured socket.

Содержание PV4-MID-PS

Страница 1: ...TRT BA PV4 MID PS TC2019 63 001 EN PV4 MID PS EN OPERATING MANUAL MULTIPLE SOCKET OUTLET...

Страница 2: ...mediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious...

Страница 3: ...bed in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Intended use The device serves as mobile multiple socket outlet The multiple socket outlet...

Страница 4: ...e description The device serves for the mobile power supply on varying application devices It comes with the following device characteristics 4 safety sockets CEE 7 3 with one PlugSafe appliance each...

Страница 5: ...t for seal 10 Safety socket cover 11 PlugSafe appliance 12 Seal 13 Anchoring for seal 14 Open end of seal 15 Terminals for neutral conductors 16 Multifunction button 17 Metrological LED 18 Backlit LC...

Страница 6: ...20 mA Accuracy Active energy class B according to EN 50470 3 MID Active energy class 1 according to EN 62053 21 NO MID Reactive energy class 2 according to EN 62053 23 S0 output Passive optoisolated...

Страница 7: ...orage temperature is the same as the range given in the Technical data chapter Start up Warning of electrical voltage Work on the electrical components must only be carried out by a qualified electric...

Страница 8: ...unauthorised access by means of one or more seals 12 Securing the multiple socket outlet can be realised whether a plug has been inserted into the safety socket 5 or not One seal 12 per plug or safet...

Страница 9: ...nctions or settings are controlled via the multifunction button 16 The symbol indicates a standard value the indicates a bidirectional value All total counter values kWh kVAh kvarh can be assigned to...

Страница 10: ...nter records the total consumption If required the partial counter can be activated in addition to record a value during a certain period of time The partial counter can be started stopped and reset 1...

Страница 11: ...unction button 16 for 3 s During these 3 seconds 3 bars will be displayed next to the Stop sequence Once the Stop sequence is completely indicated the partial counter will be stopped The symbol will b...

Страница 12: ...enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe t...

Страница 13: ...is reached the inspection intervals may be extended to max once per year Checking the residual current device Info Generally the power supply of all consumers is interrupted for testing the residual...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: