background image

  B -

 

5  

Infrared Camera – Operating Manual

 

EN

03. preparInG the Ir CaMera

Charging the Battery

Proceed as follows when charging the battery for the 
first time. This procedure also applies for all subse-
quent charging cycles, which have to be carried out 
when the symbol showing that the battery power is 
too low lights up in the display.
1. Position the edge of  
    the  charger  so  that  
    it is on the same le- 
    vel as the line on the  
    battery and insert the  
    battery in the direc- 
    tion of the arrow.
2. Attach  the  power  
    cord  to  the  battery  
    charger and plug the  
    other end into a po- 
    wer outlet.
•   The charge indicator lights up red while the battery  
    is charging and lights up green when charging is  
    complete. 

attentIOn:  It  is  extremely  important 

that  you  ensure  that  the  first  charging 

cycle lasts longer than 5 hours but not 

longer than 7 hours. Only this will ensure 

that the Li-ion cells are fully activated! 

please also ensure that you only use a 

suitable charger to charge your battery.

•   When the charging cycle has been completed, discon- 
    nect the charger from the mains supply and remove  
    the battery.
•   Your  camera  is  equipped  with  a  lithium  ion  battery  
    which does not have to be fully discharged before it  
    can be recharged. The battery does, however, have a  
    limited life and can be recharged approximately 300x.  
    We therefore recommend that, as a rule, you only re 
    charge  the  battery  when  it  is  exhausted  or  nearly  
    exhausted.
    Charging times will vary according to the surrounding  
    humidity and battery charge status.

Inserting the Battery / SD Card

Insert the battery into the camera as follows: 
1.  Check that the power is off  
    and open the battery cover  
    in the direction of the arrow. 

2. Insert  the  battery  in  the 
    direction  of  the  arrow.  

3. Insert the SD card in the  
    direction of the arrow. 

 

 

 

remove the battery pack when the camera 

 

is not in use. 

   

the  sd  Card  must  be  formatted  in  

fat32. Otherwise the Ir camera may not 

recognize the memory.

Camera

Battery Status Symbols

The following icons indicate the battery status on the 
LCD display.

Battery is sufficiently charged

            

Low battery

         

Replace or recharge battery

m

m

Содержание POWERSHRED

Страница 1: ...TROTEC GmbH Co KG Grebbener Stra e 7 D 52525 Heinsberg Tel 49 2452 962 400 Fax 49 2452 962 200 www trotec de E Mail info trotec de TRT EC060 HS 003 GB EC Series EN Infrared Camera Operating Manual B 1...

Страница 2: ...n B 17 06 Recording and Deleting B 17 Opening Images B 17 Selecting Images B 17 Selecting the Name of the Current Folder B 18 Voice Annotations B 18 Deleting Images B 18 07 Reading Out Images B 19 Rea...

Страница 3: ...turn off the power of the camera remove thebattery from the camera or unplug the power cord from the power outlet Check to see that no more smoke or fumes are coming out of the camera Stop operating i...

Страница 4: ...en the IR camera is not in use to avoid fires and other hazards Non stop operation use over a long period of time may cause the device to overheat and deform resul ting in fire Do not use the battery...

Страница 5: ...s Locking Ring Trigger Multi functional Docking Station Rear View KeyPad LCD Monitor USB Terminal Video Output Terminal Battery SD Card Cover Controls Multi function Docking Station Auto Adjust Key Po...

Страница 6: ...le charger to charge your battery When the charging cycle has been completed discon nect the charger from the mains supply and remove the battery Your camera is equipped with a lithium ion battery whi...

Страница 7: ...the operating indicator The operating indicator shows which operating status the camera is in Menu shows the menu mode Zero shows the non menu No analysis tools is selected 1 4 shows the current anal...

Страница 8: ...settings This menu item can be used to change the style of the menu system 1 Check that the IR camera is in zero mode 2 Press the MENU EN TER key then press the up s or down t arrow on the omni select...

Страница 9: ...ng target is in the centre of the display The LCD monitor will switch itself off when closed Selecting Menus and Settings You can select the settings by pressing the MENU ENTER key 1 Press the MENU EN...

Страница 10: ...ill not be deleted when you reset the menu and button operation settings to default 05 MEASURING Manual Focusing 1 Check to ensure that the IR camera is in null mode 2 Point the camera at the object y...

Страница 11: ...y and the arrow keys in order to adjust the thermal image so that it covers the visual image Moving the DuoVision area Move upwards C UPs Move downwards C DOWNt Move left C LEFT Move right C RIGHT WAR...

Страница 12: ...NU ENTER key to save the changes or press the C key to close the window without saving any new settings Information regarding image settings Auto adjust Sets the function of the A key There are three...

Страница 13: ...close the window when this step is completed Freezing Activating an Image You can freeze or activate a thermal image by pres sing the S key on the selector 1 Check that the IR came ra is in zero mode...

Страница 14: ...down t arrow on the omni selector to select the menu item Analysis then press the MENU ENTER key 3 Press the up s and down t arrow on the omni selector to select Setup then press the MENU ENTER key 4...

Страница 15: ...en 1 and 100 and describes the proportion in between 1 100 and 100 100 of the area of the LCD eg the isotherm range is between 35 C and 40 C and the Iso Alarm is 100 In this case the alarm is triggere...

Страница 16: ...andAverage temperature of the selected area Press the left or right key to select between the Max Min or Average temperature of the selected area When Area 5 is selected the Max Min and Ave rage temp...

Страница 17: ...therm range by changing the lower isotherm level IL The letters IL and IH appear in the bottom right hand corner IH is the upper threshold and IL the lower threshold of the isotherm range Removing Ana...

Страница 18: ...down arrow on the omni selec tor to select menu item Others and then press the MENU ENTER key Trigger Information Save Press the trigger to save an image Laser on Press the trigger to activate the la...

Страница 19: ...luetooth headset optional and open an image 2 Press the MENU ENTER key then press the up or down arrow on the omni selector to select the File menu and confirm 3 Press the s up or down t arrow on the...

Страница 20: ...ture when the camera is used in continuous operation Ple ase ensure that you only use original Trotec mains adapters to avoid any damage from occurring to your camera Connecting to a monitor The camer...

Страница 21: ...stall programs 1 After a few moments the following dia logue will appear 2 Select No notthistime then click Next 3 Select Installfromalist or location Advanced then click Next 4 Select Include this lo...

Страница 22: ...etooth headset first Press and hold the power button A for about 5 seconds The power indicator starts to blink in red and then blue The headset is in pairing mode after 2 seconds ThebLEDblinksmoreslow...

Страница 23: ...l Save the images onto your computer and delete them from the SD card Internal memory not formatted correctly Format the memory in FAT32 format Battery power exhausted Battery capacity reduced because...

Страница 24: ...00 1400 0 29 Melting mild steel 1600 1800 0 28 Liquid steel 1500 1650 0 42 0 53 Pure lead 1515 1680 0 42 0 45 Silver Polished Silver 100 0 05 Material Temperature C Emissivity approx Nickel Nickel chr...

Страница 25: ...na 25 600 0 55 Mild alumina 25 600 0 10 0 20 Strong alumina 25 600 0 30 0 40 Copper Cuprous oxide 800 1100 0 16 0 13 Material Temperature C Emissivity approx Non metallic materials Mica 0 94 0 95 Flam...

Страница 26: ...res Image freeze Live or freeze File function Removable SD card up to 2 GB Measurement Temperature range 20 C 250 C Accuracy 2 C or 2 Analysis Functions Spots 2 10 spots Temperature tracking Tracks th...

Страница 27: ...or 8 11V DC supply to charge the battery inside BWT 2 5 hours Environmental specification Operational temperature 15 C 50 C Storage temperature 40 C 70 C Relative humidity 10 95 Interfaces Mechanism w...

Страница 28: ...TROTEC GmbH Co KG Grebbener Stra e 7 D 52525 Heinsberg Tel 49 2452 962 400 Fax 49 2452 962 200 www trotec de E mail info trotec de...

Отзывы: