EN
Operating Manual – Portable Air Conditioner PAC 2000 E
9
Activities required before starting maintenance
• Do not touch the mains plug with wet or damp hands.
• Before any work, detach the mains plug!
Maintenance tasks, which require the housing to be
opened, must only be carried out by specialist
companies for cooling and air-conditioning or by
Trotec.
Visual check for dirt in the inside of the device
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. If you see a thick layer of dust, have the inside of the device
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
4. Put the air filter back in.
Cleaning the housing
Clean the device with a soft, damp and lint-free cloth. Ensure that
no moisture enters the housing. Do not use abrasive cleaners.
Refrigerant circuit
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and
air-conditioning or by Trotec.
Condensate discharge
In COOLING and DEHUMIDIFICATION mode condensate is formed,
which is mostly discharged via the exhaust air. Remaining
condensate accumulates at the bottom of the housing and ought
to be drained on a regular basis. If too much condensate
accumulates, the device switches off and indicates this by way of
the Condensate indication (15). Additionally, an acoustic signal
will be emitted (8x briefly). The message
H8
is also displayed.
When the indication flashes, condensate must be discharged. To
do so, please proceed as follows:
1. Switch the device off and disconnect it from the mains.
2. Carefully transport or wheel the device to a suitable location
for discharging the condensate (e.g. a drain).
3. Remove the condensation hose from the retaining clip (see
fig. A).
4. Remove the rubber stopper from the condensation hose (see
fig. B).
5. Let the condensate run, until the condensation hose is
completely drained.
6. Reattach the rubber stopper to the condensation hose and
replace the hose in the retaining clip.
– Ensure the tight fit of the rubber stopper, for otherwise
there might be uncontrolled water leakage.
Maintenance
A.
B.