4
EN
condenser dryer DH 160 / TTK 1600
Personal protective equipment
Wear safety glasses
For start-up, maintenance and troubleshooting always
wear suitable safety glasses.
Wear a protective mask
For cleaning and maintenance tasks wear an
appropriate protective mask.
Wear protective gloves
For start-up, maintenance and troubleshooting always
wear suitable protective gloves.
Wear foot protection
For transportation, start-up, maintenance and
troubleshooting always wear suitable foot protection.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The dehumidifiers of the DH and TTK series use the principle of
condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the
evaporator and the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is rewarmed at the condenser and blown out at a
temperature of approx. 5 °C above room temperature.
The drier air, thus conditioned, is mixed with the room air again
or guided to other areas via an air duct system. The humidity in
the room where the device is positioned – or in the
corresponding area – is reduced as air constantly circulates
through the device.
The condensate is fed through a pressure-resistant pipe
connection and out of the device by means of a condensation
drain hose. For the collection you can for instance place a
sufficiently dimensioned collection container beside the device.
Alternatively, the condensate can be discharged using the
installed condensate pump.
The device has a control panel for operating and controlling the
functions. Moreover, the device is fitted with an energy meter as
standard.
The device can reduce the relative humidity of a room to approx.
30 %.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.