![Trotec BM40 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/trotec/bm40/bm40_operating-manual_1172174005.webp)
EN
4
moisture measuring device BM40
Operation
Inserting the battery
Insert the supplied battery into the device before first use.
Note
Make sure that the surface of the device is dry and the
device is switched off.
+
-
1. Open the battery compartment at the rear of the device by
sliding down the cover.
2. Use the battery clip to connect the 9 V battery with correct
polarity.
3. Place the battery with the battery clip into the battery
compartment.
4. Slide the cover back onto the battery compartment until it
locks in place.
Switching the device on
Info
Note that moving from a cold area to a warm area can
lead to condensation forming on the device's circuit
board. This physical and unavoidable effect can falsify
the measurement. In this case, the display shows
either no measured values or they are incorrect. Wait a
few minutes until the device has become adjusted to
the changed conditions before carrying out a
measurement.
1. Press the power button (3) for approx. 1 s.
ð
The device starts in the measuring mode °C.
ð
The measured value is displayed in real time on the
measurement value display (8).
Selecting the measuring mode
For an increased accuracy of the measured values, which are
directly indicated in % by weight, 10 selectable material curves
are available for the following types of wood and building
materials:
Measuring
mode
Designation
Measuring range
B1
Solid brick
0 % to 20 %
B2
Anhydrite screed
0 % to 20 %
B3
Cement screed
0 % to 20 %
B4
Sand-lime brick
0 % to 20 %
B5
Gas concrete
0 % to 20 %
B6
High-insulating brick
0 % to 20 %
B7
Concrete
0 % to 20 %
H1
Hardwood (e.g. maple, birch,
beech, Douglas fir, oak, ash,
walnut)
0 % to 50 %
H2
Softwood (e.g. spruce, pine,
cherry, larch, Meranti, poplar)
0 % to 50 %
H3
Chipboard
0 % to 50 %
°C
Temperature
-10 °C to 55 °C
1. Repeatedly press the
MODE
button (3) until the desired
measuring mode is set.
Moisture measurement
Info
When pressing the contact surface of the measuring
probe against the object, apply a steady contact
pressure (approx. 10 N which corresponds to approx.
1 kg of weight force) but do not bend it to the point of
overlapping.
In order to become a better judge of what the right
level of contact pressure might be, we recommend
pressing the device a few times against a pair of
scales.
1. Use the
MODE
button (3) to select the desired measuring
mode.
2. Hold the device against the object at an angle of 90° and
make sure that the entire width of the measuring probe
rests on the contact surface.
ð
The measured value is displayed in real time on the
measurement value display (8).
Switching the device off
The device switches off automatically after approx. 10 min of
non-use.
1. Press the power button (3) for approx. 3 s.
ð
The device switches off.
Содержание BM40
Страница 1: ...TRT BA BM40 TC 002 EN BM40 EN OPERATING MANUAL MOISTURE MEASURING DEVICE ...
Страница 8: ......