moisture measuring device BM40

Operation

Inserting the battery

Insert the supplied battery into the device before first use.

Note

Make sure that the surface of the device is dry and the
device is switched off.

+

   

  -

1. Open the battery compartment at the rear of the device by

sliding down the cover.

2. Use the battery clip to connect the 9 V battery with correct

polarity.

3. Place the battery with the battery clip into the battery

compartment.

4. Slide the cover back onto the battery compartment until it

locks in place.

Switching the device on

Info

Note that moving from a cold area to a warm area can
lead to condensation forming on the device's circuit
board. This physical and unavoidable effect can falsify
the measurement. In this case, the display shows
either no measured values or they are incorrect. Wait a
few minutes until the device has become adjusted to
the changed conditions before carrying out a
measurement.

1. Press the power button (3) for approx. 1 s.

ð

The device starts in the measuring mode °C.

ð

The measured value is displayed in real time on the
measurement value display (8).

Selecting the measuring mode

For an increased accuracy of the measured values, which are
directly indicated in % by weight, 10 selectable material curves
are available for the following types of wood and building
materials:

Measuring
mode

Designation

Measuring range

B1

Solid brick

0 % to 20 %

B2

Anhydrite screed

0 % to 20 %

B3

Cement screed

0 % to 20 %

B4

Sand-lime brick

0 % to 20 %

B5

Gas concrete

0 % to 20 %

B6

High-insulating brick

0 % to 20 %

B7

Concrete

0 % to 20 %

H1

Hardwood (e.g. maple, birch,
beech, Douglas fir, oak, ash,
walnut)

0 % to 50 %

H2

Softwood (e.g. spruce, pine,
cherry, larch, Meranti, poplar)

0 % to 50 %

H3

Chipboard

0 % to 50 %

°C

Temperature

-10 °C to 55 °C

1. Repeatedly press the 

MODE

 button (3) until the desired

measuring mode is set.

Moisture measurement

Info

When pressing the contact surface of the measuring
probe against the object, apply a steady contact
pressure (approx. 10 N which corresponds to approx.
1 kg of weight force) but do not bend it to the point of
overlapping.
In order to become a better judge of what the right
level of contact pressure might be, we recommend
pressing the device a few times against a pair of
scales.

1. Use the 

MODE

 button (3) to select the desired measuring

mode.

2. Hold the device against the object at an angle of 90° and

make sure that the entire width of the measuring probe
rests on the contact surface.

ð

The measured value is displayed in real time on the
measurement value display (8).

Switching the device off

The device switches off automatically after approx. 10 min of
non-use.

1. Press the power button (3) for approx. 3 s.

ð

The device switches off.

Содержание BM40

Страница 1: ...TRT BA BM40 TC 002 EN BM40 EN OPERATING MANUAL MOISTURE MEASURING DEVICE ...

Страница 2: ...ious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with th...

Страница 3: ...ture measurement in mineral building materials and wood The measuring probe is pressed against the material to be tested The moisture level is then measured by capacitive sensors using the dielectric measurement method which is absolutely non destructive since no electrodes or probes have to be inserted into the material For an increased accuracy of the measured values which are directly indicated...

Страница 4: ...y Automatic switch off After approx 10 min Dimensions length x width x height 168 x 35 x 75 mm Weight 220 g Scope of delivery 1 x Moisture measuring device 1 x 9 V battery 1 x Quick guide Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport For transporting the device use a ...

Страница 5: ...ble material curves are available for the following types of wood and building materials Measuring mode Designation Measuring range B1 Solid brick 0 to 20 B2 Anhydrite screed 0 to 20 B3 Cement screed 0 to 20 B4 Sand lime brick 0 to 20 B5 Gas concrete 0 to 20 B6 High insulating brick 0 to 20 B7 Concrete 0 to 20 H1 Hardwood e g maple birch beech Douglas fir oak ash walnut 0 to 50 H2 Softwood e g spr...

Страница 6: ...when assessing the measurement results one has to bear in mind that the results can be influenced by various factors The measurement s accuracy depends on the contact pressure of the measuring electrodes Ideally they should be applied with a steady contact pressure of approx 10 N this corresponds to approx 1 kg of weight force however not bent to the point of overlapping Measuring depth Depending ...

Страница 7: ...e cloth Repair Do not modify the device or install any spare parts For repairs or device testing contact the manufacturer Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic...