background image

2

EN

laser distance measuring device BD22

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 3

Transport and storage........................................................... 5

Operation ............................................................................... 5

Maintenance and repair ...................................................... 11

Errors and faults.................................................................. 11

Disposal ............................................................................... 12

Notes regarding the operating manual

Symbols

Warning of laser radiation

This symbol indicates dangers to the health of persons
due to laser radiation.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

BD22

https://hub.trotec.com/?id=45780

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Do not immerse the device in water. Do not allow liquids to
penetrate into the device.

The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.

Protect the device from permanent direct sunlight.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not open the device.

Avoid looking directly into the laser beam.

Never point the laser beam at people or animals.

Only use the device, if sufficient safety precautions were
taken at the surveyed location (e.g. when performing
measurements along public roads, on building sites etc.).
Otherwise do not use the device.

Observe the storage and operating conditions (see
Technical data).

Содержание BD22

Страница 1: ...TRT BA BD22 TC210826TTRT02 001 EN BD22 EN OPERATING MANUAL LASER DISTANCE MEASURING DEVICE ...

Страница 2: ... id 45780 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Do not use the device i...

Страница 3: ...long in the hands of children Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Caution Keep a sufficient distance from heat sources Note To prevent damages to the device do not expose it to extreme temperatures extreme humidity or moisture Note Do not use abrasive cleaners or solvents to clean the ...

Страница 4: ...t value in the history No Designation Function 13 button Press briefly change measuring mode Press for a long time enable or disable acoustic signal Display 28 26 14 15 16 17 18 19 20 21 22 23 24 25 MAX MIN 29 27 No Display element 14 Battery status 15 Area measurement Volume measurement 16 Trapezoidal measurement 17 Indication of measured value 1 incl unit 18 Indication of measured value 2 incl u...

Страница 5: ...dry conditions and protect the device from external influences e g by using a suitable bag Storage When the device is not being used observe the following storage conditions dry and protected from frost and heat protected from dust and direct sunlight the storage temperature complies with the values specified in the Technical data Remove the batteries from the device Operation Inserting the batter...

Страница 6: ...hrough the history and call up the saved measured values 3 Press the button 9 for a long time to delete the saved measured values 4 Briefly press the button the button 13 or the C Off button 10 to return to the measuring menu Press the Unit button 11 to return to the pin dimension measuring mode Briefly press the C Off button 10 to return to the laser measuring mode Info It is not possible to save...

Страница 7: ...d value for a distance e g a measurement from a ground plan A 1 531m 1 Press the button 7 for a long time ð With activated signal indication function a recurring acoustic signal is emitted ð The maximum minimum and current value are indicated on the display 2 Depending on the desired measurement move the device slowly back and forth or up and down e g in the corner of a room 3 Briefly press the bu...

Страница 8: ... measurement Pythagoras Using this method the length of an unknown straight line segment can be determined via the Pythagorean Theorem This method is suitable for e g height measurements The measurement result is calculated by determining the distances A and B A B 1 Press the button 13 until the symbol for the indirect measurement appears on the display ð The upper bar hypotenuse flashes 2 First a...

Страница 9: ...etermined is displayed as result in the lower measurement value display 20 Indirect measurement of a partial height This method is suitable for measuring partial heights e g storey heights window heights etc The measurement result is calculated by determining the distances A B and C C B A 1 Press the button 13 until the symbol for the indirect measurement of a partial height appears on the display...

Страница 10: ...building To do so please proceed as follows 1 Press the button 13 until the number 10 and the symbol for the timer 27 appear on the display 2 Use the 12 and buttons 9 to set the delay time between 5 and 60 s 3 Position the device in a way that it is firmly placed on the ground and that measurements up to the desired point e g horizontally can be performed 4 Briefly press the button 7 to activate t...

Страница 11: ... proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The following fault indications can appear in the lower measurement value display Display Cause Remedy 203 The temperature is too high Allow the device to cool down Observe the permissible operating temperature according to the Technical data chapter 220 The batter...

Страница 12: ... contact an official recycling centre for electronic and electrical equipment authorised for your country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contain...

Страница 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: