Trotec AIRGOCLEAN 250 E Скачать руководство пользователя страница 7

EN

7

air cleaner AirgoClean® 250 E

Operation

Note

Avoid open doors and windows.

Control panel

14

15

16

17

18

19

21

11

22

8

9

10

12

13

20

No. Designation

Meaning

8

Light

 button

Setting the control panel
illumination.

9

PM 2.5

 button

Button for indicating the PM 2.5
fine dust value when the device
is in automatic mode

10

Ionizer

 button

Switching the plasma function
on or off
Press the button for 3 seconds if
you want to reset the 

HEPA

carbon filter degree of

contamination

 LED (

21

) or

Prefilter degree of contamination

LED (

20

) after a filter change.

11

Ionizer

 LED

Illuminated when the plasma
function is activated

12

Speed

 LED

Illuminated according to the
selected fan stage:

 = stage 1 (low)

 = stage 2 (medium)

 = stage 3 (high)

No. Designation

Meaning

13

Operating modes

 LED Illuminated according to the

selected operating mode:

Automatic mode

Night mode

Turbo mode

14

On/Off

 button

Switching the device on or off

15

Mode

 button

Selecting the operating modes

16

Speed

 button

For setting the fan speed

17

Fine dust value indica-

tion

 LED

Indication of the pollution with
particulate matter

18

Air quality fine dust

value

 LED

Illuminated according to the
measured air quality:

• blue = very good
• green = good
• orange = medium
• red = poor

19

Air quality gaseous

pollutants

 LED

Illuminated according to the
measured air pollution:

• blue = very good
• green = good
• orange = medium
• red = poor

20

Prefilter degree of

contamination

 LED

Indicates the degree of
contamination of the prefilters.
The indication 

Clean

 is

illuminated in red when the
prefilters have to be cleaned.

21

HEPA carbon filter

degree of

contamination

 LED

Indicates the degree of
contamination of the HEPA
carbon filters.
The indication 

Change

 is

illuminated in red when the
HEPA carbon filters have to be
replaced.

22

Lock

 button

Switching the locking function
on and off

Switching the device on

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.

1. Press the 

On/Off

 button (

14

) to switch the device on.

ð

The device emits an acoustic signal.

ð

The 

Speed

 LED (

12

) lights up. When the device is

switched on, it will start at the last selected fan speed.

ð

The device measures the air quality within 3 minutes.
The 

air quality

 LED (

19

) is illuminated.

Содержание AIRGOCLEAN 250 E

Страница 1: ...TRT BA AIRGOCLEAN 250E TC2020 54 002 EN AIRGOCLEAN 250 E EN OPERATING MANUAL AIR CLEANER...

Страница 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock f...

Страница 3: ...e objects Dispose of replaced filters properly especially after filtering substances hazardous to health e g asbestos or spray paint mists Never use the device as storage place or footstep Never selec...

Страница 4: ...carbon filter and a separate prefilter on each side The device uses the HEPA filters to remove bacteria viruses pollen dust mite residue mould fungus spores and other allergens from the air The integ...

Страница 5: ...it is fitted with a carry handle To make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug whi...

Страница 6: ...ects as described in the chapter Technical data A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service...

Страница 7: ...e indica tion LED Indication of the pollution with particulate matter 18 Air quality fine dust value LED Illuminated according to the measured air quality blue very good green good orange medium red p...

Страница 8: ...c mode and virus filtration Do not use the automatic mode if the device is used for virus filtration The integrated sensors only respond to air pollution caused by fine particulates pollen or possibly...

Страница 9: ...ction The Ionizer LED 11 is illuminated The device starts to filter the room air 2 Press the Ionization button 10 again to deactivate the plasma function The Ionizer LED 11 goes out Illumination You c...

Страница 10: ...s with no capacity or the air quality does not improve Check whether any windows and or doors of the room are open If so close them The HEPA carbon filter is not installed Install the HEPA carbon filt...

Страница 11: ...tachment screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign...

Страница 12: ...nters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Note Cle...

Страница 13: ...aults Make sure that the HEPA carbon filters and the prefilters are installed before switching the device on Without the HEPA carbon filters and the prefilters the device cannot fulfil its air cleaner...

Страница 14: ...26 25 7 Reinsert the prefilter 24 into the device 24 8 Put the air inlet 3 back on the device 3 9 Press the Ionizer button 10 for 3 seconds to reset the HEPA carbon filter or prefilter Cleaning the pr...

Страница 15: ...ection 220 240 V 50 Hz Power consumption 45 W Nominal current 0 17 A Sound pressure level at a distance of 1 m 56 dB A Dimensions length x width x height 360 x 360 x 710 mm Minimum distance to walls a...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: