air cleaner AirgoClean® 200 E

Assembly and start-up

Scope of delivery

1 x Device

2 x HEPA carbon filter

2 x Prefilter

1 x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

The HEPA carbon filters are pre-installed.

Note

Remove the plastic cover from the HEPA carbon filters.
To do so, please proceed as described in the chapter
Changing the HEPA carbon filter.

When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.

A

B

C

C

D

Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.

Only put up the device in an upright, stable position on firm
ground.

Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

Make sure that extension cables are completely unrolled.

Position the device near the source of air contamination.

When positioning the device, keep a sufficient distance to
heat sources.

Make sure that no curtains or other objects interfere with
the air flow.

Make sure that the air inlet and outlet are not obstructed.

Connecting the power cable

Insert the mains plug into a properly secured mains power
socket.

Содержание AIRGOCLEAN 200 E

Страница 1: ...TRT BA AIRGOCLEAN 200E TC2020 53 004 EN AIRGOCLEAN 200 E EN OPERATING MANUAL AIR CLEANER...

Страница 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock f...

Страница 3: ...ed Make sure that there are no loose items or dirt located in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety s...

Страница 4: ...tion about the device Device description The device serves to filter the room air with the aim of reducing slight and medium contaminations and odours in order to improve the air quality It is equippe...

Страница 5: ...rry handle To make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power c...

Страница 6: ...as described in the chapter Technical annex A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service On...

Страница 7: ...y LED Is illuminated according to the air quality blue good orange medium red poor 18 HEPA carbon filter LED If the Replace indication is illuminated and the last bar of the LED is illuminated in red...

Страница 8: ...OC organic chemical compounds The device cannot determine the virus load inside the room It is possible that the automatic mode indicates a good air quality even though the virus load in the room is v...

Страница 9: ...15 for 3 seconds again to deactivate the function The device switches back to the previous operating mode Memory function If you switch the device back on from standby mode the settings selected for...

Страница 10: ...them The HEPA carbon filter is not installed Install the HEPA carbon filter Check the minimum distance to walls or other objects Position the device a little more in the room s centre if required The...

Страница 11: ...t screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Страница 12: ...openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Reinsert the air filters Changing the HEPA ca...

Страница 13: ...se of the HEPA carbon filter according to the national regulations 6 Take the new HEPA carbon filter out of the plastic cover 7 Insert the new HEPA carbon filter into the device Make sure that the str...

Страница 14: ...3 h Ambient temperature 10 C to 45 C Operating range 0 to 95 RH Mains connection 220 240 V 50 Hz Power consumption 38 W Nominal current 0 17 A Sound pressure level 54 dB A Dimensions length x width x...

Страница 15: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: