EN
9
radiant heater IR 2050 / IR 3050
Start-up
Note
Please use a safety fuse (overcurrent protection device)
or a type C circuit breaker.
Note
Current peaks in the millisecond range may occur
temporarily during switch-on of the device. With an
output of up to 3,000 watts, this may cause
category 16A-B circuit breakers to trigger and to
become defective in the long run.
If necessary, have the fuses replaced by a specialist
electrical company.
Info
Odours might arise upon initial start-up or after a
longer period of non-use.
•
Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
•
Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
•
Make sure that extension cables are completely unrolled.
•
Make sure that there are no curtains or similar objects in
the immediate vicinity.
Prior to initial start-up, insert batteries in the remote control.
Connecting the power cable
•
Insert the mains plug into a properly secured mains power
socket.
•
Make sure that the power cable is guided along the back
of the device. Never guide the power cable along the front
of the device!
Operation
Note
Please use a safety fuse (overcurrent protection device)
or a type C circuit breaker.
Info
The device will only emit heat if the settings are made
via the remote control.
Info
If you switch off the device via the remote control, the
device will be set to standby mode. If standby
operation is not required, you can switch the device off
via the on/off switch (2).
Remote control
The device settings can only be made using the remote control
included in the scope of delivery.
Therefore, keep the remote control in a safe place, otherwise
the device can no longer be operated. Should you still be unable
to find the remote control, you can reorder a new one from
Trotec.
IR 2050
11
8
9
10
12
No. Designation
Meaning
8
Transmitter
Sends signals to the device.
9
Power button
For switching the device on and off
10
P2
button
To select heating capacity level 2
(1500 W)
11
P3
button
To select heating capacity level 3
(2000 W)
12
P1
button
To select heating capacity level 1
(750 W)