background image

To ensure success of installation, be sure read these instructions and review the 

diagrams thoroughly before beginning.

To avoid possible electric shock, be sure electricity is turned off at the main 

power box before wiring.

All electrical connections must be made in accordance with local codes, ordinances 

and/or the National Electrical Code.  If you are unfamiliar with the methods of installing 

electrical wiring and products, secure the services of a qualified and licensed 

electrician as well as someone who can check the strength of the supportive ceiling 

members and make the proper installations and connections.

Make sure that your installation site will not allow rotating fan blades to come into 

contact with any object.  Blades should be at least 7 feet from the floor when fan is in 

operation.

If possible, mount ceiling fan on a ceiling joist - the joist must be able to support the 

motion and weight of the moving fan.  If the fan will be mounted on a ceiling outlet box, 

a 4” x 2 1/8” deep METAL octagon box is required; one UL listed as “suitable for fan 

support”. The box and its supporting members must not be able to twist or work loose.  

DO NOT USE PLASTIC BOXES.  Installation on a concrete ceiling should be 

performed by qualified personnel.

Blades should be attached after motor housing is hung and in place.  Fan motor 

housing should be kept in carton until ready to be installed to protect its finish.  If you 

are installing more than one ceiling fan, make sure that you do not mix fan blade sets.

After making electrical connections, spliced conductors should be turned upward and 

pushed carefully up into the outlet box.  The wires should be spread apart with the 

grounded conductor and the equipment-grounding conductor on one side of the outlet 

box and the “HOT” wires on the other side.

Electrical diagrams are for reference only.  Light kits that are not packed with the fan 

must be UL/ETL listed and should be installed per the light kit’s installation instructions.

After fan is completely installed, check to make sure that all connections are secure to 

prevent fan from falling and/or causing damage or injury.

The fan can be made to work immediately after installation.  The bearings are 

adequately charged with grease, so that, under normal conditions, further lubrication 

should not be necessary.

The fan must be turned off and stopped before reversing fan direction.

This fan is suitable for sloped ceiling.

This fan is electrically reversible.

This fan includes an integrated light kit.

This fan is controlled by remote control.

This fan is suitable for indoor use, and damp location use in the US.

READ AND SAVE THESE INSTRUCTIONS

WARNING : TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY

TO PERSONS, PLEASE OBSERVE THE FOLLOWING:

1.]

2.]

3.]

4.]

5.]

6.]

7.]

8.]

9.]

10.]

11.]

12.]

13.]

14.]

15.]

Содержание 59DFG-L

Страница 1: ... warnings shown throughout Net Weight 8 46 KGS 18 6 LBS These instructions contain 4 pages Page 1 Foreword Page 2 Unpack and inspect parts contained and pre installation notes Page 3 Light Cover Installation Page 4 Hanging system installation Page 5 Wiring connections Canopy and Blade installation and Remote Setting Model No 59DFG L HS 1233 F ...

Страница 2: ...housing is hung and in place Fan motor housing should be kept in carton until ready to be installed to protect its finish If you are installing more than one ceiling fan make sure that you do not mix fan blade sets After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor a...

Страница 3: ...cket Downrod Assembly Canopy Yoke Cover Motor Assembly Bulb 60W Max Blade x5 Remote Receiver Remote Transmitter Remote Wall Bracket Wall Bracket Screws x2 Wire Nuts x 5 Turn off power at breaker box to avoid possible electrical shock Use metal outlet box suitable for fan support Outlet box must support 35 lbs min Note 1 Note 2 WARNING blades should be at least 7 feet from floor Glass Shade with Gr...

Страница 4: ... fixture Install Bulb Note Four screws are pre installed on Light Pan for light socket fixture installation You will need to remove these screws Screws for Light Grill 3 Lower Light Grill Align Holes After feeding the light wires through the center hole lower the Light Pan onto motor assembly aligning the two loosened screws with the large end of the key holes Rotate Light Pan slightly so that scr...

Страница 5: ...t downrod through canopy and yoke cover and feed motor wires through downrod Loosen 2 downrod jam screws at yoke Insert downrod assembly into yoke Insert the cross pin through yoke downrod and secure with washer and cotter pin Tighten both downrod jam screws to further secure downrod Pull down the yoke cover to cover yoke Mounting Bracket Ridge Ball Groove 2C Hanging the fan Lift fan assembly onto...

Страница 6: ...remaining canopy screw into the other hole and tighten both canopy screws 4 Installing the canopy Note Two screws are pre installed on mounting bracket for canopy installation You will need to remove one and loosen the other slightly Note Do not squeeze all the wires while inserting the receiver into the mounting bracket 3A Insert receiver into mounting bracket Follow separate instructions enclose...

Отзывы: