background image

KOMPERNASS GMBH · BURGSTRASSE 21 · D-44867 BOCHUM

www.kompernass.com

ID-Nr.: KH3002-06/09-V2

6

MOBILE POWER SUPPLY

KH 3002

MOBILE POWER SUPPLY

Operating instructions

  

  

 

  

 

Содержание KH 3002

Страница 1: ...KOMPERNASS GMBH BURGSTRASSE 21 D 44867 BOCHUM www kompernass com ID Nr KH3002 06 09 V2 6 MOBILE POWER SUPPLY KH 3002 MOBILE POWER SUPPLY Operating instructions ...

Страница 2: ...KH 3002 q A w e r t y u i o a s B d f g h j k C F D E ...

Страница 3: ...he power supply on 7 Ending the supply of electricity 7 Possible faults in the event of non functionality 8 Power supply over the screw connections 8 Carrying out connections using the banana plugs 8 Carrying out connections with the bare ends of fixed appliance cables 8 Carrying out connections over a loose cable 8 Fuses 9 Changing a round fuse 9 Changing a flat fuse 9 Changing a cable fuse 9 Cle...

Страница 4: ...o use check that all items are present and free of visible damage 1 Energy Station KH 3002 1 Carrying strap 1 Power supply unit 1 Vehicle adapter 1 Adapter cable 5 Adapter plugs Technical Data Energie Station Rechargeable gel battery 12 V 7 Ah Low voltage sockets 3 V 4 5 V 6 V 9 V 12 V unstabilised 1 A Vehicle socket 12 V 10 A Screw connections 12 V 10 A for max 2 mins Connector power pack Power s...

Страница 5: ... the power supply unit only replace it with one of the same model To avoid risks arrange for defective power plugs and or cables to be replaced at once by qualified technicians or our Customer Service Department Never submerge the appliance or the power supply unit in water Wipe it only with a slightly damp cloth Do not expose the appliance to rain and never use it in a humid or wet environment En...

Страница 6: ...g it beforehand Before taking the appliance into use check to ensure that the Energy Station the connection cables and the power supply unit are in a defect free condition Danger NEVER use a damaged connection cable Risk of short circuit Charging with the mains power plug Attention Explosive Gas Avoid flames and sparks During charging ensure that there is sufficient ventilation 1 Insert the applia...

Страница 7: ...er the low voltage socket max 1 A Caution Before performing any connections always check to ensure that both the appliance to be supplied and the Energy Station are switched off Place the main switch 2 in the OFF position centre position In this way you can avoid damage through connec tion faults Carrying out connections A total of 5 low voltage connection sockets 4 from 3 12 V are available for t...

Страница 8: ...you can withdraw the adapter cable plugs from both the appliance and the Energy Station Possible faults in the event of non functionality If neither of the two LEDs 5 and 6 light up after switching on then the 10 amp fuse 8 on the Energy Station might have blown Changing fuses is described in more detail in the section Fuses Should an LED light up on the Energy Station after switching on but the a...

Страница 9: ...d cable and 12 V plug Positive and Negative have the correct polarity 1 Insert the appliance connector of the supplied vehicle adapter cable in the socket on your appliance 2 Insert the 12 V plug of the vehicle adapter resp the appliance being powered in the 12 V 10 A socket 3 on the Energy Station Switching the power supply on 1 Place the main switch 2 at ON your appli ance will now be supplied w...

Страница 10: ...appliance only by way of the screw connections 9 as described here Carrying out connections using the banana plugs 1 The screw connections 9 are hollow to accom modate so called banana plugs If such are provided on your appliance cable you can insert these in the screw connections 9 from the top instead of screw connecting Danger Extremely high current flows are possible here ones that are even ca...

Страница 11: ...t fuse Pull out the flat fuse 8 at the rear of your ap pliance e g with long nose pliers Insert a new 10 A C10 fuse Changing a cable fuse Unscrew the cable fuse cap on the 12 V plug of the vehicle adapter Insert a new 1 A T1A 250 V fuse If the fuse blows again immediately after the app liance is connected the appliance is burdening the Energy Station with excessive power consumption or it is defec...

Страница 12: ...iance in a dry place Disposal Do not dispose of the appliance in your normal domestic waste This product is subject to the provisions of European Directive 2002 96 EC Dispose of this appliance through an approved waste disposal centre or at your community waste facility Observe the currently applicable regulations In case of doubt please contact your waste disposal centre Disposal of batteries cel...

Страница 13: ...ects not for wearing parts or for damage to fragile components This product is for pri vate use only and is not intended for commercial use The warranty is void in the case of abusive and improper handling use of force and internal tampe ring not carried out by our authorized service branch Your statutory rights are not restricted in any way by this warranty DES Ltd Tel 0870 787 6177 Fax 0870 787 ...

Страница 14: ......

Отзывы: