Aqua-X Controller 

Содержание Aqua-X NFS-1

Страница 1: ...Aqua X Controller...

Страница 2: ...their irrigation systems The system could control pumps by 110V Control Board and solenoid valves by 24V Control Board With the massive control outputs user could manager delivery schedules for multi...

Страница 3: ...qua X through the 110V CONTROL port 24V Control Board 6 outputs each 110V Control Board 6 outputs each and Program Device Station 1 output each can be used together but each Aqua X can only control up...

Страница 4: ...elease the bracket from the unit mount the bracket to a wall or surface place the unit back on the bracket and press the 4 tabs back in to lock the unit in place CONNECTIONS DC INTERNET MICRO SD SENSO...

Страница 5: ...o the 110V Control Board The 110V Control Board and Program Device Station can be chained together with T Splitter through the 110V CONTROL socket 4 Water Detectors Connection Connect the Water Detect...

Страница 6: ...turn on and boot up If it is the first time you have used the NFS 1Controller when you power on the NFS 1 Controller the Welcome screen page will display and remind user to press ENTER to set system t...

Страница 7: ...enu Page Water Detector Page Alarm Message Page 1 On the Main Menu page press LEFT button to get access to Water Detector page It shows output s that has have been associated with the connected Water...

Страница 8: ...L port or the 110V Control Board is not connected to the power supply the LCD screen will show No 110V Board Online Please make sure the RJ12 cable is correctly connected and power on the 110V Control...

Страница 9: ...OWN button to change the minute Press ENTER button and the MINUTE of Time will be highlighted and blinking user can press UP or DOWN button to change the minute Press ENTER button and the SECOND will...

Страница 10: ...me Off time Times 110 V A1 08 00 05m 10s 01h 10m 3 Start On time Off time Times 110 V A1 08 00 05m 10s 01h 10m 3 Start On time Off time Times 110 V A1 08 00 05m 10s 01h 10m 3 Start On time Off time Ti...

Страница 11: ...leak detection and the symbol is a triangle shown in the Aqua X Controller When WD 1 detects water leakage it will send alarm message to your Smartphone one minute later You can also check the alarm...

Страница 12: ...ion Board 110 V C 110 V C1 110 V C2 110 V C3 110 V C4 110 V C5 110 V C6 Control Board Interface Dot Indicating Assigned Output Dot Indicating Assigned Output Water Detector 1 Water Detector b Assignme...

Страница 13: ...The LCD screen will display the MIN value and MAX value Press ENTER button to activate the setting page and the MIN value will be highlighted and blinking Press UP button or DOWN button to change the...

Страница 14: ...hlighted and blinking Press UP or DOWN button to convert the temperature format between F and C Finally press ENTER button to confirm and save the change The LCD screen will display Setting saved or S...

Страница 15: ...ime Setting Mar 17 2018 11 45 09 Time Setting 11 45 09 Press ENTER button and the HOUR will be highlighted and blinking Press UP or DOWN button to change the hour Press ENTER button again and the curs...

Страница 16: ...detected Please insert SD card NOTE For the Firmware Update and Iot FW Update make sure to insert the MicroSD card with the latest version of upgrade software e Calibration When the Calibration colum...

Страница 17: ...erial Number System Reset Calibration Emergency Stop Board Auto Resume in 30 min Board System F T emp F ormat Time Setting Serial Number System Reset Calibration Resume f Emergency Stop The Emergency...

Страница 18: ...BELL icon is flashing It indicates that there is an alarm state Alarm status includes temperature pH EC value exceeds range orwater sensor alarm OA6 24 OA6 110 DSP 1 or WD 1 can not be added to the A...

Страница 19: ...pplication is available for 24V Control Board 6 outputs each 110V Control Board 6 outputs each and Program Device Station 1 output each but control up to 30 outputs per set pH Alarm Setpoint Range 0 1...