
TL-3120 Motion Control User Manual
WWW.SZTROCEN.COM
80
Table7-5-1 Auto Reset Settings Instruction
Name
Instruction
X HardLimit
HardLimit switch of X axis. If use HardLimit, enable the function here.
Y HardLimit
HardLimit switch of Y axis. If use HardLimit, enable the function here.
Z HardLimit
HardLimit switch of Z axis. If use HardLimit, enable the function here.
7.6 Function Config
On the
Manufacture Params Settings
page, move cursor to
【
Function
Config
】
and press
【
Enter
】
. Press
【←】
【→】
to able or disable the
【
Z-
Axis For Autofocus
】
function and press
【
Enter
】
to save settings.
Figure7-6-1 Function Config Interface