E
PTE
PLE
PTE
RUE
PTE
PLE
PTE
90
CZ
Symptom
Problem
Suggested remedy
Saw will not operate
Power lead not plugged in
Ensure that the power lead is connected to the
power supply
Power fault, fuse or circuit breaker tripped
Check the power supply
Brushes worn or sticking
Disconnect power, open brush caps and ensure brushes move freely in the holders. Check whether
brushes require replacing as outlined in the maintenance section.
Lead damaged
Use authorised service centre** to repair or replace the lead
Faulty switch
Use authorised service centre** to repair or replace the switch
Faulty motor
Use authorised service centre** to repair or replace the motor
Poor performance
Extension lead too long or undersized
Use extension lead heavy enough to carry the
current
Blunt or damaged blade
Re-sharpen or replace blade
Motor is overloaded
Reduce pushing force on saw. Ensure the cut isn’t closing and pinching the blade.
Tool is overheating
Turn off the tool and let it cool down to room temperature. Inspect and clean the ventilation slots.
Vibration or abnormal noise
Accessory not secured
Ensure that the saw blade is fully tightened in the
arbor washers
Moving parts excessively worn
Use authorised service centre** to repair or replace
Mechanical obstruction
Use authorised service centre** to repair or replace
Armature has shorted sections
Use authorised service centre** to repair or replace
Motor runs but blade won’t spin
Blade retaining nut is loose
Tighten blade retaining nut, ensure the arbor
washers are correctly itted
Broken gear shaft or teeth
Use authorised service centre** to repair or
replace
Saw depth adjustment not holding
Depth adjustment lever requires tightening
Reposition the depth adjustment lever as
described in 'Adjusting the depth locking lever
tension'
Heavy sparking occurs inside motor housing
Brushes not moving freely
Disconnect power, remove brushes, clean or
replace
Armature short circuited or open circuited
Use authorised service centre** to repair or replace
Commutator surface not clean
Use authorised service centre** to repair or replace
Retractable guard will not close, or is slow to close
Return spring detached or broken
Re-attach or replace spring (use only genuine
Triton replacement parts)
Guard is bent
Straighten it or contact authorised service centre** to repair or replace
Mechanism fouled by sawdust
Clean and lightly lubricate fouled mechanism
If a problem cannot be resolved using the above advice do not tamper with the saw - visit www.tritontools.com to ind your nearest Triton ofice for assistance.
** Visit www.tritontools.com to ind your nearest authorised service centre.