Conversion Between MicronNav Responder and Transponder
MicronNav System
0656-SOM-00001-07
139
© Tritech International Ltd.
At the bottom-right of the page is the
Comms Mode
selection panel. Set the
Aux
to
RS232
and click the
Baud Rates
button at the bottom-left of the page to open the
Comms Setup
window. Set the
Async 1 [Head Aux/Aif Rat]
baud to 9600 (for both
Lo Speed
and
Hi Speed
).
Confirm the settings and close the
Comms Setup
page and then confirm the
Sonar Setup
and return to the
Seanet Setup
page. Remove power from the Micron Sonar/ROV and
connect the Aux port of the micron Sonar to the Main port of the Responder using an
appropriate interconnect lead.
Switch on power to the Micron Sonar/ROV and check the Micron reappears in the
Seanet
Setup
page. This complete the installation configuration.
11.3.2. Configure Seanet Pro Responder Mode
Run the
Seanet Pro
program by clicking on the
Seanet Pro
shortcut on the desktop. The
following screens should be displayed but if not navigate to the
Applications
menu and
select
Sonar Nav
from the list. If video is also required, select
Sonar Nav Video