Merlin
0711-SOM-00001, Issue: 03
14
© Tritech International Ltd.
5. Maintenance
Warning
Do not power the pump or hydraulic valve actuators until all hoses are properly
connected to the pump.
There is a serious risk of injury to fingers if inserted into either the power water
intake or the pump delivery port.
If undertaking any testing operations suitable guards and other safety measures
must be in place.
5.1. Tools Required
The following tools are required to work on the pump:
• 22mm open ended spanner
• 13mm open ended spanner
• 18m ring spanner (for actuator stripdown)
• 10mm Allen key
• 8mm Allen key
• 6mm Allen key
• 5mm Allen key
• 2.5mm Allen key
• Dead blow hammer
• Loctite - "Studlock" for reassembly
For detailed assembly procedures refer to Appendix B,
5.2. Basic Procedures
Hydraulic Motor Shaft Seals
The pumps are fitted with either an 'H' (red) or 'V' (brown) type seal. The type V is the standard
seal and is high pressure, high temperature.
Replacement of seals with anything other than a genuine seal (or
Tritech International Ltd
supplied seal) will invalidate the warranty.
Pre-dive
Visual check for external damage.
Содержание Merlin
Страница 22: ...Appendix A Motor Protector Assembly Procedure ...
Страница 24: ...Appendix B Merlin Assembly Figure B 1 Main Pump ...
Страница 26: ...Figure B 2 Merlin Body Merlin Body Assembly Instruction ...
Страница 28: ...Figure B 3 Merlin Motor Mount Assembly ...
Страница 30: ...Figure B 4 Merlin Diffuser Assembly ...