Model #: SU10KRT3U
SmartOnline 10kVA On-Line Double-Conversion UPS, 9U Rack/Tower, 208/120V or 240/120V Hardwire output
Highlights
10kVA / 10,000VA / 9000W on-line double-conversion UPS; 0.9 power factor
208/120V or 240/120V 50/60Hz output; Economy mode option
9U Rack / Tower compatible; Hot-swappable power and battery modules
USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card
options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hardwire input (3 wire); Hardwire output
Description
Tripp Lite SU10KRT3U 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical network
applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications.
Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included stepdown transformer
with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced
availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers,
computer rooms, network closets and rugged industrial locations.
Package Includes
SU10000RT3UPM 3U UPS power module
BP240V10RT3U external battery pack
SU10KXFMRRT3U step down transformer with manual bypass switch
Four post compatible rack rail kit (3 sets)
Tower stands for upright tower configuration
PowerAlert software, complete data cabling and user manual
Features
Tripp Lite SU10KRT3U 10kVA / 10,000VA / 9000 watt on-line, double-conversion UPS system in 9U total rack/tower configuration (3U UPS
power module, 3U external battery pack and 3U step-down transformer)
Included stepdown transformer with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in
output power to connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input and output connections
Maximum installed rack depth of only 32.5 in. / 82.6cm
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions
and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with
enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS
types
Maintains full-time sine wave output within 2% of 208/240 and 120V nominal at 50/60Hz during brownouts as low 100V and overvoltages as