background image

1111 W. 35th Street Chicago, IL 60609 USA • 773.869.1234 • www.tripplite.com

Owner’s Manual

PowerVerter

®

Ultra-Compact DC-to-AC Inverters

PV150, PV375, PV500 & PV600

1

2

3

4

5

6

PV375 Front View

PV375 Rear View

PV150 Front View

PV150 Rear View

1

7

2

3

4

6

Feature Identification

Lighted ON/OFF Switch:

move to ON (“I”) position to power connected equipment;

switch will illuminate. Move to OFF (“O”) position to stop powering connected
equipment.

AC Outlet(s):

accept 120V AC equipment you would normally plug into a wall outlet.

DC Fuse(s) 

(externally mounted on PV150 and PV375; internally mounted on

PV500 and PV600)

:

protect vehicle battery from damaging overload. If fuse blows,

replace with standard automotive fuse of equal amperage. CAUTION: installing
non-rated fuses could cause equipment damage and void your warranty.

Vehicle Lighter/Accessory Plug (PV150 & PV375 only):

connects to a standard

12V DC vehicle lighter/accessory outlet.

DC Power Terminals (PV500 & PV600 only):

directly connect to your battery terminals

with user-supplied cables.

Cooling Fan (PV375, PV500 & PV600 only):

maintains internal cooling.

Ultra-Compact, Lightweight Metal Case

Mounting Flanges (PV500 & PV600 only):

provide fixed mounting, if desired.

Install and tighten four user-supplied screws through mounting flanges and into a rigid
horizontal surface. Mount Inverter before DC battery connection. 

Low Battery Alarm (internal, not shown):

detects low voltage and shuts down

Inverter to preserve vehicle battery. If alarm sounds, turn Inverter OFF and run
engine to recharge battery.

Overload Alarm (internal, not shown):

detects wattage overload on Inverter outlets

and shuts down Inverter as a protective measure. If alarm sounds, turn Inverter OFF
and reduce wattage load (by unplugging high-wattage devices).

Safety

Important Safety Instructions! Save These Instructions!

This manual contains important instructions and warnings that
should be followed during the installation, operation and storage 
of all Tripp Lite Inverters.

Warning!

• Do not use a Tripp Lite PowerVerter Inverter in life support or healthcare 

applications where a malfunction or failure of a Tripp Lite PowerVerter Inverter 
could cause failure or significantly alter the performance of a life support device 
or medical equipment.

• Do not operate your Inverter near flammable materials, fumes or gases.

Caution!

• Since the Inverter requires adequate ventilation during operation, do not block fan 

or cooling vents or cover the Inverter, and do not operate near vehicle heating 
vents or in direct sunlight. Keep the Inverter dry at all times and disconnect when 
not in use.

• Since the Inverter case will get hot (130° - 140° F) during continuous extended  

use, use care when handling it. Do not place it near surfaces or materials 
affected by this level of heat.

• Turn OFF connected equipment before starting your engine. DO NOT plug a surge 

suppressor, line conditioner or UPS system into the Inverter. If you attach AC 
extension cords, use the heaviest practical gauge.

• Before connecting a battery charger or adapter, check its manual to make sure that the

Inverter’s specifications (including output waveform) fall within its recommendations.

Congratulations! Your new PowerVerter Inverter will give you years of reliable, carefree service. Use it to convert DC (battery) power into 110-120V AC (household) power to run
a variety of electronics: notebook computers, game systems, battery chargers, small TVs/VCRs and more! The Inverter’s PWM (Pulse Width Modulated) sinusoidal wave is suitable
for almost all loads.

1

7

2

3

4

PV500/PV600 Front View

PV500/PV600 Rear View

1

7

2

6

5

Operation

Step 1 (PV150 & PV375 models):

Plug Inverter into vehicle lighter/accessory outlet.

Step 1 (PV500 & PV600 models):

First mount inverter, if desired. With user-supplied

cables,* connect the Inverter’s negative DC terminal directly to your battery’s negative
terminal; connect the Inverter’s positive DC terminal through a UL-listed fuse and fuse
block** and directly to your battery’s positive terminal. CAUTION! Observe proper
polarity. Reversed polarity will blow the PV500’s and PV600’s internal fuses. To access
internal fuses, disconnect equipment and battery from the PV500 or PV600. Then
unscrew and remove end panels to access fuses. Replace blown fuses with an equal
number of new fuses of the same type and amperage. Replace end panels and screws.

Tighten your Inverter’s and battery’s DC terminals to approximately
2.25 Newton-meters (1.85 foot lbs.) of torque to create an efficient
connection and to prevent excessive heating at this connection.
Insufficient tightening of the terminals could void your warranty.
It is recommended that you solder cable ends and insulate the 

terminals at the battery. WARNING! Do not connect your Inverter directly to output
from an alternator rather than a battery or battery bank.

* The PV500’s and PV600’s output is limited by the length and gauge of user-supplied cables. See cable sizing guide on back page. Shorter
and heavier gauge cable maximizes output (especially important when operating heavy-draw equipment). An excellent source of cables are
battery jumper cables. ** Required by NEC article 551. Mount within 18 inches of the battery.

Step 2: Turn on Inverter.

Step 3: Plug equipment into the Inverter.

Determine your equipment’s total wattage.* Do not connect more watts than your
Inverter’s Output Power (Maximum Continuous Watts) rating—either 150, 375, 500 or
600, see

Specifications

. See back page for typical equipment runtimes. Also see back

page for important note concerning the limitations of vehicle electrical systems.

* Wattage ratings are usually listed in equipment manuals or on nameplates. If your equipment is rated in amps, multiply that number
times AC utility voltage to determine watts. (Example: a ¼ in. drill requires 2½ amps. 2½ amps × 120 volts = 300 watts.)

7