12
Specifications
MODEL NUMBER:
PV1000HF
PV1800HF
PV3000HF
Continuous Power (@ 20° C):*
1000 Watts
1800 Watts
3000 Watts
Double Boost™ Peak Surge Power:*
2000 Watts
3600 Watts
6000 Watts
DC Input Volts (Nominal):
12 VDC
12 VDC
12 VDC
DC Input Voltage Range:
10 - 15 VDC
10 - 15 VDC
10.5 - 15 VDC
DC Input Connection:
User Supplied Cables
User Supplied Cables
User Supplied Cables
Output Volts (Nominal):
120 VAC
120 VAC
120 VAC
Output Frequency (Nominal):
60 Hz, ± 0.5%
60 Hz, ± 0.5%
60 Hz, ± 0.5%
Efficiency:
Up to 94%
Up to 94%
Up to 94%
Output Waveform:
Modified Sine Wave
Modified Sine Wave
Modified Sine Wave
* DoubleBoost duration (instantaneous). Actual output depends on battery age, battery charge level and ambient temperature.
Minimum Recommended Cable Sizing Chart
†
Always loosely twist each pair of cables (one positive and one negative) together. Use in conjunction with DC wiring
connection instructions in the Battery Connection section. Using 4 conductors is recommended (but not required) to
obtain maximum output power from PV3000HF models.
Wire Gauge
2 Conductors (all models)
4 Conductors (PV3000HF only)
Watts
6
4
2
0
00
Twin 00
500
15 ft
25 ft
39 ft
62 ft
79 ft
158 ft
700
11 ft
18 ft
28 ft
44 ft
56 ft
112 ft
1000
N/R
12 ft
20 ft
31 ft
39 ft
78 ft
2000
N/R
N/R
N/R
16 ft
20 ft
40 ft
2400
N/R
N/R
N/R
13 ft
16 ft
32 ft
3000
N/R
N/R
N/R
10 ft
13 ft
26 ft
† N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the
performance)
Tripp Lite Inverters include a Battery Charge Conserver (Load Sense) Control which saves battery power by
allowing users to set the minimum load level at which the unit’s inverter turns on. Users can significantly
reduce the No Load DC Input Current to a very low amperage power level with the use of this control.