background image

10 millisecond automatic transfer between line and battery power supports UPS protection during blackouts and voltage fluctuations for

equipment compatible with a one half-cycle transfer time

750 watts continuous AC output in inverter mode

Double Boost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds (see specification

chart)

OverPower inverter output supports longer duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions.

(For best results, utilize OverPower usage for as short of a duration as possible, ensure battery bank and cabling is able to provide full

nominal DC voltage under load and allow inverter/charger to fully cool before and after OverPower usage.)

3-stage, selectable 5/20 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging

Protected hardwire bolt-down input lugs safely accept heavy gauge input wiring from attached battery bank

Dual C13 output receptacles pass 120V line power or inverter output through to connected equipment

Reliability enhanced large-transformer design with secure mounting flanges and protected DC wiring terminals

Moisture-resistant construction enables vehicular or marine operation in high humidity environments

3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, CHARGE-ONLY to

maintain a full battery charge when AC is present without auto transfer and SYSTEM OFF settings

Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status

Set of 4 configuration dip switches support wet/gel battery charging profiles, charger enable/inhibit, and selectable 144/163/182/201V AC

low voltage auto transfer during brownouts

Set of 4 additional configuration dip switches support 4 levels of charger limiting relative to output load size, a battery equalization program

and battery charger low/high settings

Resettable 3A charger AC input breaker and resettable 4A AC output breaker and automatic 2-speed cooling fan protect the inverter from

load and temperature-related failures 

Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system

Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop

Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory). Optional APSRM4 accessory

also includes user-configurable jacks to support inverter shutoff or startup as a vehicle ignition is engaged

Specifications

OVERVIEW

Intended
Application

Emergency Home Power

OUTPUT

Frequency
compatibility

50 Hz

Output watts

750

Continuous output
capacity (watts)

750

Peak output
capacity (watts)

1500

Output nominal
voltage

230V

Output voltage
regulation

LINE POWER (AC): Maintains 230V nominal sine wave output from line power source. INVERTER POWER (AC):
Maintains PWM sine wave output voltage of 230 VAC (+/-5%).

Output frequency
regulation

50 Hz (+/- 0.3 Hz)

Overload protection

Includes 3A input breaker dedicated to the charging system and 4A output breaker for AC output loads.

Outlet quantity /
type

2 AC outlets

INPUT