background image

2A

Limited Warranty

Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a period of one year (except for outside of U.S.A., Canada and Mexico—120 days) from the date of retail purchase by end user

Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized
Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of pur-
chase. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way, including opening of the unit’s casing for any reason. This warranty applies only to the orig-
inal purchaser who must have properly registered the product within 10 days of retail purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclu-
sion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POS-
SIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Important Safety Instructions

SAVE THESE  INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite
Inverter/Chargers.

Location Warnings

• Install your Inverter/Charger (whether for a mobile or stationary application) in a location or compartment that minimizes exposure to 

heat, dust, direct sunlight and moisture.

• Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit 

and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might 
accumulate. Mounting should be in the driest location available.

• Leave a minimum of 5 cm clearance at front and back of the Inverter/Charger for proper ventilation. The heavier the load of connected 

equipment, the more heat will be generated by the unit.

• Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.

• Do not install near flammable materials, fuel or chemicals.

• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the 

unit's internal cooling, eventually causing product damage not covered under warranty.

Battery Connection Warnings

• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.

• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be 

installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some 
ventilation to outside air. 

• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.

• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury 

or property damage could result.

Equipment Connection Warnings

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the 
failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this
equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.

• Corded models: Do not modify the Inverter/Charger’s plug or receptacle in a way that eliminates its ground connection. Do not use 

power adapters that will eliminate the plug’s ground connection.

• Connect your Inverter/Charger only to a properly grounded AC power outlet or hardwired source. Do not plug the unit into itself; this 

will damage the device and void your warranty.

• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of the 

Inverter/Charger.

Operation Warnings

• Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.

• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any 

service work, the battery supply and AC input connection should therefore be disconnected.

• Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode 

Switch should be in the OFF position. Dangerous arcing may result.

200711152 93-2752 230V APS OM.qxd  11/29/2007  2:15 PM  Page 2

Содержание APINT Series

Страница 1: ...ection Automatic Overload Protection Ideal Output for All Loads including computers Frequency Controlled Output Fast Load Switching Balanced Load Sharing Better for Your Batteries Faster Battery Recha...

Страница 2: ...water might accumulate Mounting should be in the driest location available Leave a minimum of 5 cm clearance at front and back of the Inverter Charger for proper ventilation The heavier the load of co...

Страница 3: ...utility or generator supplied AC power when used with a user supplied cable with country specific plug Hardwire AC Input Output Terminal Strip not on corded models securely connects the Inverter Charg...

Страница 4: ...CHARGE ONLY this light will FLASH to alert you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Invert...

Страница 5: ...tage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Select Load Sharing OPTIONAL Your Inv...

Страница 6: ...ly from full output at 33 of the Inverter Charger s load rating to about 33 of full output at full load Least Limiting B1 Up B2 Down Charger limiting begins at when the Inverter Charger s load reaches...

Страница 7: ...ur batteries with utility or genera tor supplied AC power Compensate for inefficiency by multiplying this number by 1 2 This will give you a rough estimate of how many amp hours of battery power from...

Страница 8: ...izontal surface leaving the heads slightly raised Slide the Inverter Charger back over the fasteners to engage the mounting slots molded on the bottom of the Inverter Charger cabinet Install and tight...

Страница 9: ...iring Though your Inverter Charger is a high efficiency con verter of electricity its rated output capacity is limited by the length and gauge of the cabling run ning from the battery to the unit Use...

Страница 10: ...te over the hardwire terminal box Remove the knockout covers closest to the desired electrical source and to your equipment Attach 1 28 cm diameter conduits user supplied to the knockouts and thread w...

Страница 11: ...e fuse Battery cabling is loose Check and tighten or replace cabling Unit has shut down due to battery overcharge preventing Disconnect any auxiliary chargers Reset by moving Operating Mode battery da...

Страница 12: ...es integrada Isobar Protecci n autom tica contra sobrecarga Salida ideal para cualquier carga incluyendo computadoras Salida controlada por frecuencia R pida conmutaci n de carga Reparto de carga bala...

Страница 13: ...a de 5 cm en la parte frontal y posterior del inversor cargador para una adecuada ventilaci n A mayor carga del equipo conectado la unidad generar m s calor No instale el inversor cargador directament...

Страница 14: ...CA de la red o suministrada por un generador cuando se emplea con un cable suministrado por el usuario con alg n enchufe de uso local especial Regleta cableada de terminales de entrada salida de corri...

Страница 15: ...e NO suministrar energ a de corriente alterna en ausencia de alimentaci n de la red o de un generador o en casos de sobrevoltaje o bajo voltaje Indicador INV Inversi n amarillo Esta luz se ILUMINAR CO...

Страница 16: ...dad de veces que su unidad cambia a bater a debido a variaciones de voltaje Conmutadores DIP Grupo B Seleccionar reparto de carga OPCIONAL Su inversor cargador presenta un cargador de bater a de alta...

Страница 17: ...alida completa a plena carga M nima limitaci n B1 arriba y B2 abajo La limitaci n del cargador comien za cuando la carga del inversor cargador alcanza el 66 de su capacidad total de carga La salida de...

Страница 18: ...por 1 2 Esto le dar un estimado grueso de cuantos amperios hora de energ a de bater a de una o varias bater as debe conectar a su inversor cargador NOTA La capacidad de amperios hora de una bater a u...

Страница 19: ...el inversor cargador hacia atr s sobre los tornillos para enganchar las ranuras de montaje moldeadas en la parte inferior del gabinete del inversor cargador Instale y apriete dos tornillos de 6 mm sum...

Страница 20: ...iciencia su capacidad de salida est limitada por la longitud y el calibre del cableado desde la bater a hasta la unidad Use la longitud m s corta y el calibre de mayor di metro del cableado m ximo cal...

Страница 21: ...as cubiertas de los agujeros ciegos m s cercanas a la fuente el ctrica deseada y a su equipo Conecte tubos de 1 2 de di metro suministrados por el usuario a los agujeros ciegos y pase los conductores...

Страница 22: ...Revise y reemplace el fusible El cableado de la bater a est flojo Revise y ajuste o reemplace el cableado La unidad se ha apagado debido a sobrecarga de la bater a Desconecte cualquier cargador auxili...

Страница 23: ...ection automatique contre les surcharges Sortie id ale pour toutes les charges y compris les ordinateurs Sortie fr quence contr l e Commutation rapide de la charge Partage quilibr e de la charge Meill...

Страница 24: ...placement le plus sec possible Maintenez un d gagement minimal de 5 cm l avant et l arri re de l onduleur chargeur pour garantir une bonne circulation d air Plus la charge de l quipement branch est lo...

Страница 25: ...cteur ou produit par une g n ratrice l aide d un c ble quip d une fiche sp cifique au pays fourni par l utilisateur Barrette raccordement fixe de bornes d entr e de sortie CA pas sur les mod les cordo...

Страница 26: ...us avertir que l onduleur de l unit est OFF ferm et Ne fournira Pas de courant CA en l absence d une source du secteur ou d une g n ratrice ou dans des situations de basse ou haute tension Voyant jaun...

Страница 27: ...int haut de tension d entr e CA ou en abaissant le point bas de tension d entr e CA vous r duirez le nombre de fois o votre unit passera sur batterie cause de variations de tension Groupe B de commuta...

Страница 28: ...de l onduleur chargeur environ 33 de la sortie pleine pleine charge Limitation minimale No B1 en haut ET No B2 en bas La limitation du chargeur commence lorsque la charge de l ond uleur chargeur atte...

Страница 29: ...ne estimation grossi re de la puissance de batterie en A h d une ou de plusieurs batteries que vous devrez brancher votre CO REMARQUE La puissance nominale en A h des batteries est habituellement donn...

Страница 30: ...ement relev es Glisser l onduleur chargeur entre les attaches pour engager les fentes de fixation moul es la base du bo tier de l onduleur chargeur Installer et serrer deux attaches de 6 mm po fournie...

Страница 31: ...leur chargeur est un c o n v e r t i s s e u r hautement efficace d lectricit sa puissance nominale de sortie est limit e par la longueur et le calibre des connecteurs CC du c blage reliant la batteri...

Страница 32: ...t le couvercle de la bo te de bornes raccordement fixe Enlever les entr es d fon ables les plus proches de la source lectrique d sir e et de votre quipement Fixer des tubes protecteurs de 1 28 cm de d...

Страница 33: ...e a saut V rifier et remplacer le fusible Le c blage de la batterie est l che V rifier et resserrer ou remplacer le c blage L unit s est teinte cause d une surcharge emp chant des D brancher tous les...

Страница 34: ...Espa ol 12 Fran ais 23 PowerVerter APSX APSINT 12 24 36 230 50 230 50 12 24 36 1111 W 35th Street Chicago IL 60609 USA 773 869 1212 www tripplite com 750 1250 2007 PowerVerter Tripp Lite Tripp Lite A...

Страница 35: ...Tripp Lite 120 Tripp Lite Tripp Lite Tripp Lite RMA Returned Material Authorization Tripp Lite Tripp Lite 10 TRIPP LITE TRIPP LITE Tripp Lite Tripp Lite Tripp Lite 5 UPS Uninterruptible Power Supply...

Страница 36: ...RGE ONLY IEC 320 IEC 320 Tripp Lite APSRM4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 OUTPUT NEUTRAL OUTPUT HOT GROUND INPUT NEUTRAL INPUT HOT FOR USE WITH COPPER WIRE ONLY 1 2 4 3 5 9 10 11 13 8 14 2012 2424 3...

Страница 37: ...ONLY OFF OFF AUTO REMOTE CHARGE ONLY Tripp Lite APSRM4 Tripp Lite LINE AUTO REMOTE CHARGE ONLY INV LOAD 100 OFF AUTO REMOTE CHARGE ONLY BATTERY 91 81 90 61 80 41 60 21 40 1 20 0 OFF AUTO REMOTE CHARGE...

Страница 38: ...A3 A4 INPUT C B 10A OUTPUT C B 12A B4 B3 B2 B1 A4 A3 A2 A1 DIP B DIP A DIP A 201 A4 A3 182 A4 A3 163 A4 A3 144 A4 A3 182 DIP B DIP A1 A2 A3 A4 B2 B1 B B B B APSINT2424 APSINT3636 278 259 APSX750 APSX1...

Страница 39: ...ualize Reset DIP 3 B1 B2 230 B1 B2 33 33 33 B1 B2 66 66 66 B1 B2 B1 B2 B3 B4 B1 B2 B3 B4 B1 B2 B3 B4 B1 B2 B3 B4 B1 B2 B3 B4 750 1250 8 Tripp Lite APSRM4 B1 B2 B3 B4 OFF LESSER LOAD ON MAX GREATER LOA...

Страница 40: ...40A 6 Marine 8D DIP Tripp Lite 1 1 3 1 3 230 300 75 80 2 1 12 24 3 2 1 2 20 55 50 9 30 4 3 Tripp Lite 1000 Tripp Lite Tripp Lite 300 220 20 540 300 140 100 540 540 12 45 45 5 1 2 270 270 30 9...

Страница 41: ...41A Tripp Lite Tripp Lite Tripp Lite 750 1250 6 6 2012 2424 3636 6 6 A B C A B C A C B M A C B M APS M M M M M M 11 4 cm 17 1 cm 20 cm 14 16 cm 38 12 cm M M M M...

Страница 42: ...2A 12 24 36 12 24 36 12 12 12 24 24 12 24 2 12 6 24 4 6 12 Tripp Lite X 12 24 36 UL 45 2 0 5 4 3 2 1 XB XB 4 1 2 3 24B 6B 6B 6B 6B 1 2 2 2 2 4 3 5 2 0 200 3 5 8 AWG American Wire Gage Tripp Lite 45 18...

Страница 43: ...43A 100 IEC 320 IEC 320 1 28 OUTPUT NEUTRAL OUTPUT HOT GROUND INPUT NEUTRAL INPUT HOT FOR USE WITH COPPER WIRE ONLY 5 4 1 3 2 1 2 3 4 5 DoubleBoostTM Tripp Lite 10 OverPowerTM Tripp Lite 1 150...

Страница 44: ...EMOTE CHARGE ONLY CHARGE ONLY AUTO REMOTE OFF 1 AUTO REMOTE CHARGE ONLY Tripp Lite OFF 1 AUTO REMOTE CHARGE ONLY OFF 1 AUTO REMOTE CHARGE ONLY Tripp Lite OFF 1 AUTO REMOTE CHARGE ONLY Tripp Lite LOW 5...

Отзывы: