Страница 1: ...tems Models OMNIVSX850A OMNIVSX1000A OMNIVSX1500A Series Numbers AG 04F5 AG 04F1 AG 04F2 Owner s Manual 1111 W 35th Street Chicago IL 60609 USA tripplite com support Copyright 2020 Tripp Lite All rights reserved ...
Страница 2: ...right on a sturdy flat surface Do not block fans or ventilation holes as this will seriously inhibit the unit s internal cooling and cause product damage not covered under warranty UPS Connection Warnings Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS Do not modify the UPS plug and do not use an adapter that would eliminate...
Страница 3: ...e of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not connect surge protectors or extension cords to the output of your UPS This might damage the UPS and may affect the surge protector and UPS warranties Connect the UPS to an outlet that is adequately protected against excess currents short circuits and earth faults as part of the building...
Страница 4: ...following precautions should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect the charging source and load prior to installing or maintaining the battery Remove battery grounds during installation and maintenance to reduce likelihood of shock...
Страница 5: ...rload the UPS if the total volt amp VA ratings for all the equipment connected to the BATTERY SURGE PROTECTED outlets exceed the UPS output capacity To find your equipment s VA ratings look on their nameplates If the equipment is listed in amps A multiply the number of amps by 230 to determine VA For example 1A 230 230VA If you suspect you have overloaded the outlets check Load Meter screens see D...
Страница 6: ...lug equipment into the UPS You will overload the UPS if the total volt amp VA ratings for all the equipment connected to the BATTERY SURGE PROTECTED outlets exceed the UPS output capacity To find your equipment s VA ratings look on their nameplates If the equipment is listed in amps A multiply the number of amps by 230 to determine VA For example 1A 230 230VA Turn the UPS on Press and hold the pow...
Страница 7: ... greater than 110 The LCD screen reports that AVR Auto Voltage Regulation buck boost circuits are active any time the line power icon is flashing 1 Output Voltage 2 Input Voltage 3 Load Note The LCD touchscreen automatically turns off in line power mode 20 seconds after it was last touched To re activate the LCD for an additional 20 seconds touch the screen Operating Mode Alarm Description Battery...
Страница 8: ...TPUT SHORT Disconnect load s from UPS outlets Power off UPS and contact Tripp Lite Technical Support for assistance F02 OVER LOAD Remove excess load check load meter on LCD for load status F03 OVER CHARGE Turn unit off unplug UPS and contact Tripp Lite Technical Support for assistance F04 BATTERY LOW VOLTAGE Charge UPS for 24 hours If problem persists replace battery and contact Tripp Lite Technic...
Страница 9: ...3 Battery Backup Surge Protected Outlets These outlets offer battery backup support and premium surge suppression for critical devices requiring battery backup support 4 USB Communication Port This port can connect your UPS to any computer for automatic saves and unattended shutdown in the event of a power failure Use with Tripp Lite s PowerAlert Software available as a FREE download at tripplite ...
Страница 10: ...l and in compliance with UL 1989 CAUTION Risk of energy hazard Before replacing batteries remove conductive jewelry such as chains wristwatches and rings High energy passing through conductive materials may cause severe burns CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to instructions 5 AC Power Input Use the Australian power cord to co...
Страница 11: ...at the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the product to the dealer Instead visit tripplite com support 3 If the problem requires service visit tripplite com support and click the Product Returns link From here you can request a Returned Material Authorization RMA number which is required for service This sim...
Страница 12: ...model number of the product EMC Specifications for Models with EMC Category C2 Approval Select Models WARNING This is a category C2 UPS product In a residential environment this product may cause radio interference in which case the user may be required to take additional measures WEEE Compliance Information for Tripp Lite Customers and Recyclers European Union Under the Waste Electrical and Elect...