TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
22 / 110
Entry Description
Sub-index
Description
Access
PDO Mapping
Value Range
Default Value
01h
Restore all parameters
rw
no
UNSIGNED32
—
02h
Restore communication parameters
rw
no
UNSIGNED32
—
03h
Restore device profile parameters
rw
no
UNSIGNED32
—
04h
Restore motor axis 0 parameters
rw
no
UNSIGNED32
—
Table 28: Entry Description (1011
h
)
3.1.11
Object 1014
h
: COB-ID Emergency Object
This object defines the COB-ID of the emergency object (EMCY).
Object Description
Index
Name
Object Type
Data Type
1014
h
COB-ID emergency object
Variable
UNSIGNED32
Table 29: Object Description (1014
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
UNSIGNED32
80
h
+ Node ID
Table 30: Entry Description (1014
h
)
3.1.12
Object 1015
h
: Inhibit Time EMCY
The inhibit time for the EMCY message can be adjusted via this entry. The time has to be a multiple of
100
µs
.
Object Description
Index
Name
Object Type
Data Type
1015
h
COB-ID emergency object
Variable
UNSIGNED16
Table 31: Object Description (1015
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
UNSIGNED16
0
Table 32: Entry Description (1015
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany