![Trinamic TMCM-1021 TMCL Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/trinamic/tmcm-1021-tmcl/tmcm-1021-tmcl_manual_1163069019.webp)
TMCM-1021 TMCL
™
Firmware Manual • Firmware Version V1.42 | Document Revision V1.10 • 2018-JAN-09
19 / 109
Branch Commands
Mnemonic
Command number
Meaning
JA
22
Jump always
JC
21
Jump conditional
COMP
20
Compare accumulator with constant value
CSUB
23
Call subroutine
RSUB
24
Return from subroutine
WAIT
27
Wait for a specified event
STOP
28
End of a TMCL program
Table 8: Branch Commands
3.6.4
I/O Port Commands
These commands control the external I/O ports and can be used in direct mode as well as in standalone
mode.
I/O Port Commands
Mnemonic
Command number
Meaning
SIO
14
Set output
GIO
15
Get input
Table 9: I/O Port Commands
3.6.5
Calculation Commands
These commands are intended to be used for calculations within TMCL applications. Although they could
also be used in direct mode it does not make much sense to do so.
Calculation Commands
Mnemonic
Command number
Meaning
CALC
19
Calculate using the accumulator and a constant value
CALCX
33
Calculate using the accumulator and the X register
AAP
34
Copy accumulator to an axis parameter
AGP
35
Copy accumulator to a global parameter
ACO
39
Copy accu to coordinate
Table 10: Calculation Commands
For calculating purposes there is an accumulator (also called accu or A register) and an X register. When
executed in a TMCL program (in standalone mode), all TMCL commands that read a value store the result
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.