background image

Page  10 of 14

                  Part Number 8519184-0000  Rev: B

Field Replaceable Units FRU’s

Description                                                                 

Trimm Part Number

Power Supply, 350W (PFC)

5417240-0100

Power Supply, 350W (non-PFC)

5420009-0100

Drive Canister (2 each),

5417239-002*

Drive Canister (8 each),

5417239-008*

End Caps (pair),

5417418-010*

Alarm Board (standard JBOD) Assembly

5418868-0100

Alarm Board (Castle UR16R JBOD) Assembly

5419533-0000

Saf-Te Board Assembly

5418887-0100

Front Display Board

5417335-0100

Fan Assembly (Auxiliary Blower Fan)

5417241-0100

Where * = color:
1 = Light Grey
4 = Charcoal
5 = Black
6 = Taupe

Power Supply Assembly
350W (PFC)
5417240-0100

Fan Assembly
Auxiliary Blower
5417241-0100

Front Display Board
Part Number 5417335-0100

Drive Canister (Module)
Available in several color schemes and
shipped in groups of 2 or 8
5417239-xxxx

Slides

Lever to install or
remove canister

Light Pipes for
Drive Activity and
Drive Failure

Power Supply Assembly
350W (non-PFC)
5420009-0100

Please Note the type of Handle to determine which type power supply you
have, as they are not interchangeable

Содержание UR8J2-4 Series

Страница 1: ...rt Number 8519184 0000 Rev B Installation Guide for UltraRAID Family UR8J2 4xxx Ultra Rack SCSI 3 Ultra 2 Low Voltage Differential LVD UT8J2 4xxx Ultra Tower SCSI 3 Ultra 2 Low Voltage Differential LV...

Страница 2: ...Part Number 8519184 0000 Rev B...

Страница 3: ...k 5 Install Feet Tower Enclosure only 5 Install Remove End Caps Rack mount Enclosure only 6 Drives into Canister 6 Canister into Enclosure 7 Power Supply Install Remove 7 Fan Auxiliary Blower Install...

Страница 4: ...s are those that conform to SCSI 3 specifications with SCA 2 connections The single ended and host only low voltage differential LVD versions support drives up through SCSI 3 Fast 20 Ultra for transfe...

Страница 5: ...lbs 29 55 kg Rack Total with eight canisters and no drives 59 0 lbs 26 82 kg Tower Total with eight canisters and no drives 79 0 lbs 35 91 kg Power Supply 350 watt dual redundant hot pluggable A C 10...

Страница 6: ...of 1 channel of 8 drives or 2 channels of 4 drives see Convert 2 x 4 Configuration to a 1 x 8 or vice versa The host connections are identified as SCSI A and SCSI B SCSI A is on the right side rack o...

Страница 7: ...4 For a 1 x 8 configuration install the a SCSI jumper cable between the second connectors for the SCSI A and SCSI B connectors The host is connected to SCSI A while SCSI B is either terminated or conn...

Страница 8: ...caps from the front ears use a screwdriver at the bottom of the end caps to release the flexible latch then insert enclosure into the rack and attach the front ears of the enclosure to the rack Reinse...

Страница 9: ...flexible flange to disengage it from the indent and permit the bottom of the cap to be pulled forward to remove the cap s Figure 3 End Cap Install Remove Illustration Drives into Canisters Mount the d...

Страница 10: ...4 turn the power switch off remove the attached power cord undo the thumbscrews two for each supply then grab handle and pull to the rear To install insert supply into opening in enclosure to point w...

Страница 11: ...enclosure fans middle LED and temperature bottom LED within the enclosure The temperature LED is red if the enclosure temperature exceeds 45 C Green indicates okay operation while red indicates a prob...

Страница 12: ...losure are mounted on this board Also the optional Saf Te board is mounted on this board as a daughter board IF the optional Saf Te board is installed then the alarm board CANNOT be removed from the r...

Страница 13: ...nt Display Board 5417335 0100 Fan Assembly Auxiliary Blower Fan 5417241 0100 Where color 1 Light Grey 4 Charcoal 5 Black 6 Taupe Power Supply Assembly 350W PFC 5417240 0100 Fan Assembly Auxiliary Blow...

Страница 14: ...t Number 5417847 0100 Cable multimode external Part Number 5417823 0100 1 foot Part Number 5417823 0200 3 foot Part Number 5417823 0300 10 foot Part Number 5417823 0400 25 foot Alarm Board Assembly Pa...

Страница 15: ...emission construction techniques This equipment generates uses and may emit radio frequency energy If not installed in accordance with the information provided in this manual it may cause interferenc...

Страница 16: ...fically authorized by the company to sell such products The company s sole obligation and the purchaser s remedy pursuant to this warranty are limited to repair or replacement at the company s option...

Страница 17: ...Trimm Technical Support via US Mailing Address Trimm Technologies Inc 350 Pilot Road Las Vegas Nevada 89119 Phone 702 263 2310 Fax 702 361 6067 Email support trimm com Web Site http www trimm com UK...

Страница 18: ...hnologies Inc 350 Pilot Rd Las Vegas Nevada 89119 USA Phone 702 263 2310 Fax 702 260 3443 http www trimm com Trimm Technologies LTD Millennium Way East Phoenix Centre Nottingham England NG8 6AR Phone...

Отзывы: