INSTALLATION Page 1-7 

USER GUIDE Page 8-23

 

 

revised June 2017 

 

 
IMPORTANT: The wiring installation for this meter, especially the shunt installation 

must be performed by someone knowledgeable in proper wiring, electrical practices, 
and safety. If you do not have this knowledge please have someone install it who does, 
or at least get some competent help to supervise the installation. 

 

 
To install:  

1. Please read or scan two pages of introductory information in section A.  
2. Consult drawings Figure 1 and 2 (pages 7-8). 
3. Follow step by step installation instructions in section B.  
4. Program the two most important parameters into meter (section C1).   

 

A. Before installing the TriMetric meter:

 

B. How to Install Meter and Shunt

:  

C1. How to determine program item P3: “battery system capacity

” 

C2. How to program your meter for the 100A/100mV shunt.

 

C3. Optional: Now or later you may wish to program P4, P5, P6

 

Warranty and customer service 

Limited warranty 

The  TriMetric  TM-2030  is  warranted  for  three  years  against  any  manufacturing  defect.  Any  meter  not  meeting  the 
specification or rated performance shall be replaced or repaired, at Bogart Engineering’s discretion, provided it has not 
been subjected to abuse or misapplication.  For warranty service, please email 

[email protected]

.  A return 

merchandise authorization is required for all merchandise to be returned to Bogart Engineering. 

How to obtain customer service 

Please  review  our  support  page  before  attempting  to  contact  us.    Our  distributors  are  able  to  answer  simple 
questions  about  Bogart  Engineering  products.    For  technical  support,  send  an  email  to 
bogart@bogartengineering and someone will assist you. 

 

BOGART ENGINEERING  

www.bogartengineering.com 

Содержание TM-2030-A

Страница 1: ...and Shunt C1 How to determine program item P3 battery system capacity C2 How to program your meter for the 100A 100mV shunt C3 Optional Now or later you may wish to program P4 P5 P6 Warranty and custo...

Страница 2: ...ndard double gang electrical boxes available in hardware stores For detailed drawings see application notes on the Bogart Engineering web site under SUPPORT APPLICATION NOTES Mounting Drawings for TM...

Страница 3: ...to accommodate the maximum system charging or discharge amps from the battery It should have suitable bolt lugs at each end One end will connect to one large bolt on the shunt the other end to the ba...

Страница 4: ...y you will also need to connect a fifth wire from the positive post of this battery to meter as shown in wiring diagram The terminal block on the TriMetric circuit board accommodates wire size from 16...

Страница 5: ...goes to proper B1 terminal on the meter See wiring Figure 2 If you installed the more common 500A 50mV shunt proceed to next step 7 If you used the 100A 100mV shunt see section C2 below How to program...

Страница 6: ...h for total volts When you put them in parallel then you add the amp hours of each string or battery Total volts are SAME as each When you have batteries that are both in series and in parallel first...

Страница 7: ...the shunt which should be used for current sensing wires only For measurement accuracy don t connect wires containing high currents to these connections 2nd BATTERY SYSTEM TO MEASURE VOLTS ONLY if use...

Страница 8: ...therwise this meter will not give correct data on Battery full and days since charged Additional information and reference 3 Beyond Beginners Instructions for Operating Levels L2 L3 L4 4 History Data...

Страница 9: ...ging for technical people to diagnose system problems For each of the last 5 days the daily maximum battery voltage level and minimum charging amps is recorded as well as the percent of overcharge ach...

Страница 10: ...battery voltage low b LO these See section 2 2 for details TM 2030 Operation Summary Push quickly to make display toggle through SELECT Push and hold for 3 seconds until pops into display Immediately...

Страница 11: ...n optional feature that is designed to help you keep your batteries maintained which can remind you to periodically charge your batteries to maximize their life It comes from the factory turned OFF Mo...

Страница 12: ...es The items H7 through H9 refer to data during the last 5 days A charge discharge cycle refers to the time beginning from a fully charged battery followed by partial discharge to less than 98 and end...

Страница 13: ...into OBSERVE mode Now either continue programming as described in step 2 or to get back to regular displays push SELECT repeatedly PROGRAM MODE NUMBER Used by SC 2030 charger PROGRAMMABLE DATA and ADJ...

Страница 14: ...at 0 0 25 0 hours 0 0 For exact description see charging profile graphs near page 14 of SC 2030 Solar Charge Controller User s Manual See section 6 2 step 4 and section 6 4 P14 P15 For SC 2030 charger...

Страница 15: ...h with 1 2 in mounting tabs top and bottom 10 8 x 7 6 x 3 5 cm TM 2030 A 4 1 2 x 4 3 4 panel with circuit board 1 1 8 max in deep 11 4 x 12 1 x 2 85 cm History data retained in memory when power turne...

Страница 16: ...pleted so that the amp hours from full goes to a negative value equal to the capacity programmed in P3 then the Battery full goes to zero 6 3 What History data can tell you about your system See the c...

Страница 17: ...than 100 efficient possibly a charging source possibly solar controller or chassis ground connected to the negative post of the battery instead of on the load side of the shunt so the meter is not mea...

Страница 18: ...ons for observing and changing programming items is in section 5 P1 and P2 Charged setpoint voltage and charged setpoint amps Purpose of data The charged voltage P1 and amp P2 setpoints provide inform...

Страница 19: ...2030 is switched to L3 or L4 level Use program P7 to select L3 or L4 Program modes P8 P14 P15 P16 P20 P21 and P22 are only used only with the optional SC 2030 charge controller See SC 2030 Solar Char...

Страница 20: ...for them you can extend their life to maximize their return to you 1 Charging to correct voltage Charging for sufficient time Charging at frequent intervals 2 Not often letting them become totally dis...

Страница 21: ...just previously discharged is often recommended for AGM batteries the number is 104 108 Very few chargers use this method but our SC 2030 solar charger has this capability when paired with the TM 2030...

Страница 22: ...Other manufacturers may have different recommendations It is usually advisable to check water levels in the batteries after equalization as it causes some water loss After equalization has taken place...

Страница 23: ...item P7 on page 6 of these instructions for how to set to L2 or L3 5 Push RESET to view and record all data moving to right back in time in table except for H1 1 History Number X 1 Most Recent X 2 X 3...