Note:
Radio performance and coverage typically improves as the
height increases.
l
The radio signals to and from the CONN-2000, within the Fresnal zone, will
not be obstructed.
l
Any nearby structures do not block line of sight radio coverage.
l
Clear of thick trees or brush at installation site. The site must be maintained
free of trees in the foreseeable future.
Note:
Foliage in the line-of-sight to other devices can degrade radio
performance.
Grounding Requirements
These requirements identify the primary ground point for the device location.
Warning:
A proper ground protects both the CONN-2000 and the
equipment connected. Ground protection is essential if it is installed on
a tall structure or in an area where lightning occurs. It is highly recom-
mended to use an Ethernet surge suppressor device.
The techniques described here are general guidelines and do not constitute a com-
prehensive guide covering all installation scenarios.
For maximum protection, and if lightning is a threat in your area, consult a specialist in
lightning and transient protection who is familiar with your operating environment.