Technical Design-in Guide Engine LLE G2 PRE KIT | 03-2020 | 1.2 | en
Thermal Aspects
c
42 / 63
LLE G2 24x280mm 700lm PRE
Forward current
tp temperature
L90 / F10
L90 / F50
L80 / F10
L80 / F50
L70 / F10
L70 / F50
125 mA
55 °C
30,000 h
>50,000 h
>50,000 h
>50,000 h
>50,000 h
>50,000 h
60 °C
22,000 h
>50,000 h
41,000 h
>50,000 h
>50,000 h
>50,000 h
65 °C
16,000 h
37,000 h
31,000 h
>50,000 h
46,000 h
>50,000 h
70 °C
12,000 h
27,000 h
23,000 h
>50,000 h
35,000 h
>50,000 h
LLE G2 24x280mm 1500lm PRE
Forward current
tp temperature
L90 / F10
L90 / F50
L80 / F10
L80 / F50
L70 / F10
L70 / F50
330 mA
55 °C
30,000 h
>50,000 h
>50,000 h
>50,000 h
>50,000 h
>50,000 h
60 °C
22,000 h
>50,000 h
41,000 h
>50,000 h
>50,000 h
>50,000 h
65 °C
16,000 h
37,000 h
31,000 h
>50,000 h
46,000 h
>50,000 h
70 °C
12,000 h
27,000 h
23,000 h
>50,000 h
35,000 h
>50,000 h
7.1.2. Requirements for the heat sink
The heat sinks must be dimensioned to provide adequate cooling capacity.
The R value is important for selecting an appropriate heat sink. This value depends on the light output of the module and on the
th
ambient temperature in which the module is to be operated. The R value of the heat sink must be smaller than the required R
th
th
value.
...
I
NOTICE
Please check the information on the operating temperature and the requirements for cooling in the module data sheets.
I
NOTICE