Rated supply voltage

220 – 240 V

AC voltage range

198 – 264 V

Mains frequency

50 / 60 Hz

LED module forward voltage range

10 – 54 V

Output current

see chapter 5.3

Starting time

< 0.5 s from detection of emergency 
event

Overvoltage protection

320 V (for 48 h)

U-OUT (including open- / short-circuit and 
double load)

60 V

Max. open circuit voltage

60 V

Ambient temperature range ta

-25 ... +55 °C

Max. casing temperature tc

80 °C

Mains voltage changeover threshold

according to EN 60598-2-22

Mains surge capability (between L – N)

1 kV

Mains surge capability (between L/N – PE) 2 kV
Integrated DALI bus power supply IPS

50 mA

Type of protection

IP20

Functional test

Weekly 5s test

Duration test

Yearly 1 h / 2 h / 3 h test

Life-time

up to 100,000 h

Dimensions LxWxH

179 x 30 x 21 mm

EM converterLED PRO NF MH/LiFePO4 50 V

Powered DALI PRO NFC series

 

30

21

30

179

169.2

Position A
   3 h

No duration 
link    2 h

Position B
   1 h

Note: LED Driver supplied with duration link in 3 hours position. Duration link must be set 
before battery and mains connection.

Ordering data

Type

1

Article 

number

Rated 

duration

Packaging, 
carton

Packaging, 
pallet

Weight 
per pc.

EM converterLED PRO 302 MH/LiFePO4 50V

 

89800640

1/2/3 h 10 pc(s).

1,600 pc(s). 0.075 kg

EM converterLED PRO 303 MH/LiFePO4 50V

89800641

1/2/3 h 10 pc(s).

1,600 pc(s). 0.075 kg

EM converterLED PRO 304 MH/LiFePO4 50V

89800642

1/2/3 h 10 pc(s).

1,600 pc(s). 0.075 kg

Test switch EM3

 

A

CCES

-

SORIES

 

Ordering data

Type

Article number

Packaging, 
bag

Packaging,
carton

Weight 
per pc.

Test switch EM 3

 

89899956

25 pc(s).

200 pc(s).

0.013 kg

Status indication bi-colour LED

 

A

CCES

-

SORIES

 

Specific technical data

Type

Battery 

technology

Rated 

duration

Typ. λ  

(at 230 V, 

50 Hz)

Typ. output 

power 

P emergency

Mains current in charging operation

Rated power in charging operation

Initial charge

3

Fast recharge

3

Trickle charge

23

Initial charge

3

Fast recharge

3

Trickle charge

23

EM converterLED PRO 302  
MH/LiFePO4 50V

 

NiMH

1 h

0.6C

1.5 W

16 mA

18 mA

16 / 12 mA

2.1 W

2.5 W

2.1 / 1.6 W

2 h

0.6C

1.5 W

21 mA

22 mA

18 / 12 mA

2.8 W

3.0 W

2.4 / 1.6 W

3 h

0.6C

1.5 W

21 mA

22 mA

18 / 12 mA

2.8 W

3.0 W

2.4 / 1.6 W

LiFePO

4

1 h

0.6C

1.5 W

16 mA

16 mA

16 / 12 mA

2.3 W

2.3 W

2.3 / 1.6 W

2 h

0.6C

1.5 W

22 mA

22 mA

22 / 12 mA

3.0 W

3.0 W

3.0 / 1.6 W

3 h

0.6C

1.5 W

22 mA

22 mA

22 / 12 mA

3.0 W

3.0 W

3.0 / 1.6 W

EM converterLED PRO 303  
MH/LiFePO4 50V

 

NiMH

1 h

0.6C

2.5 W

17 mA

20 mA

17 / 12 mA

2.3 W

2.8 W

2.3 / 1.6 W

2 h

0.6C

2.5 W

24 mA

25 mA

20 / 12 mA

3.2 W

3.4 W

2.7 / 1.6 W

3 h

0.6C

2.5 W

24 mA

25 mA

20 / 12 mA

3.2 W

3.4 W

2.7 / 1.6 W

LiFePO

4

1 h

0.6C

2.5 W

22 mA

22 mA

22 / 12 mA

3.0 W

3.0 W

3.0 / 1.6 W

2 h

0.6C

2.5 W

27 mA

27 mA

27 / 12 mA

4.0 W

4.0 W

4.0 / 1.6 W

3 h

0.6C

2.5 W

27 mA

27 mA

27 / 12 mA

4.0 W

4.0 W

4.0 / 1.6 W

EM converterLED PRO 304  
MH/LiFePO4 50V

NiMH

1 h

0.6C

3.5 W

18 mA

22 mA

18 / 12 mA

2.5 W

3.1 W

2.5 / 1.6 W

2 h

0.6C

3.5 W

26 mA

27 mA

22 / 12 mA

3.8 W

4.1 W

3.0 / 1.6 W

3 h

0.6C

3.5 W

26 mA

27 mA

22 / 12 mA

3.8 W

4.1 W

3.0 / 1.6 W

LiFePO

4

1 h

0.6C

3.5 W

22 mA

22 mA

22 / 12 mA

3.0 W

3.0 W

3.0 / 1.6 W

2 h

0.6C

3.5 W

27 mA

27 mA

27 / 12 mA

4.0 W

4.0 W

4.0 / 1.6 W

3 h

0.6C

3.5 W

27 mA

27 mA

27 / 12 mA

4.0 W

4.0 W

4.0 / 1.6 W

EM = Emergency

2

 

In case of NiMH batteries: Intermittent charge is used. Value 1 is for 4 min. charge on / Value 2 is for 16 min. charge off. In case of LiFePO

batteries voltage dependent constant current charging is used. Value 1 is 

for charge on / Value 2 is for charge off.

3

 

Integrated DALI bus power supply is switched OFF. With the Integrated DALI bus power supply switched ON and fully loaded the input power and current is increased by 1 W and 6 mA in any charging mode.

Содержание EM converterLED ST MH/LiFePO4 50 V

Страница 1: ...angeover and delayed power switching for the LED Driver Constant power output Two colour status display LED Black Box data recording Interfaces DALI interface for controlled testing and monitoring Near field communication NFC Battery management NiMH LiFePO4 Intelligent charge system Deep discharge protection Polarity reversal protection for battery via polarized connector plug Automatic detection ...

Страница 2: ...ency Mains current in charging operation Rated power in charging operation Initial charge3 Fast recharge3 Trickle charge23 Initial charge3 Fast recharge3 Trickle charge23 EM converterLED PRO 302 MH LiFePO4 50V NiMH 1 h 0 6C 1 5 W 16 mA 18 mA 16 12 mA 2 1 W 2 5 W 2 1 1 6 W 2 h 0 6C 1 5 W 21 mA 22 mA 18 12 mA 2 8 W 3 0 W 2 4 1 6 W 3 h 0 6C 1 5 W 21 mA 22 mA 18 12 mA 2 8 W 3 0 W 2 4 1 6 W LiFePO4 1 h...

Страница 3: ...ct description Two colour status display LED Green system OK red fault Plug connection Status indication bi colour LED ACCES SORIES Ordering data Type Article number Packaging bag Packaging carton Weight per pc LED EM bi colour 1 0 m CON 89800273 25 pc s 200 pc s 0 015 kg LED EM bi colour high brightness HO 1 0 m CON 89800275 25 pc s 200 pc s 0 015 kg LED EM bi colour 0 6 m CON 89800474 25 pc s 20...

Страница 4: ...g connection for LED Driver Connection Cable NiMH ACCES SORIES Ordering data Type Article number Packaging bag Packaging carton Weight per pc CONNECTION CABLE NiMH 500mm 28002462 10 pc s 200 pc s 0 015 kg Product description Extension cable for LiFePO4 batteries Cable length 500 mm 3 pole plug connection Extension Cable LiFePO4 ACCES SORIES Ordering data Type Article number Packaging bag Packaging...

Страница 5: ...ure rate of 0 2 per 1000 operating hours Expected life time with LiFePO4 batteries DALI power supply off Type ta 40 C 45 C 50 C 55 C EM converterLED PRO 302 MH LiFePO4 50V tc 65 C 70 C 75 C 80 C life time 100 000 h 100 000 h 100 000 h 79 000 h EM converterLED PRO 303 MH LiFePO4 50V tc 65 C 70 C 75 C 80 C life time 100 000 h 100 000 h 100 000 h 78 000 h EM converterLED PRO 304 MH LiFePO4 50V tc 65 ...

Страница 6: ...a standard LED LED Driver and one LED module for mains and emergency operation EM converterLED PRO with a standard LED LED Driver and series operation of LED modules Neutral Bat P O Lout Lin N DA DA L L N EM ConverterLED PRO Neutral DALI DALI Un Switched Line Test switch Indicator LED Switched Line out Switched Line in Control gear LED LED Control gear LED Module Emergency LED control gear max 150...

Страница 7: ...hed Line in DALI bus Integrated power supply Battery One LED module is operated in emergency mode All LED modules are operated in mains mode 8 9 mm wire preparation 0 5 1 5 mm 3 2 Wiring type and cross section Solid wire with a cross section of 0 5 1 5 mm Strip 8 9 mm of insulation from the cables to ensure perfect operation of terminals Wiring LED module LED Driver supply 3 3 Battery connection L...

Страница 8: ...etal cable clips louver etc To ensure that a luminaire containing LED emergency units complies with EN 55015 for radio frequency conducted interference in both normal and emergency mode it is essential to follow good practice in the wiring layout Within the luminaire the switched and unswitched 50Hz supply wiring must be routed as short as possible and be kept as far away as possible from the LED ...

Страница 9: ...M converterLED PRO MH LiFePO4 50V 90 130 130 130 180 260 260 260 3 6 A 120 μs 5 Electrical values 5 1 Maximum loading of automatic circuit breakers 5 2 Insulation matrix Mains Switched Live Battery LED Test switch Indicator LED DALI Mains Switched Live Battery LED Test switch Indicator LED DALI Represents basic insulation Represents double or reinforced insulation When using a non SELV LED Driver ...

Страница 10: ...tery discharge current tolerance EM converterLED PRO 303 MH LiFePO4 50V Article number 89800641 NiMH battery 3 6 V battery voltage 770 830 mA battery discharge current tolerance LiFePO4 battery 3 2 V battery voltage 900 960 mA battery discharge current tolerance LED current mA VLED V VLED V LED current mA EM converterLED PRO 304 MH LiFePO4 50V Article number 89800642 NiMH battery 4 8 V battery vol...

Страница 11: ...f EM converterLED The max allowed output voltage U OUT of the associated LED Driver applied to the EM converterLED output is 450V voltage withstand between adjacent contact of the single switching relay of the EM converterLED The max allowed LED load of the associated LED Driver is 150 W in operation The load must be an LED module Check compatibility with the carried out function test duration at ...

Страница 12: ...f the mains supply and battery supply to the EM converterLED PRO the unit will commence charging the batteries for 20 hours initial charge Afterwards the module will conduct a commissioning test for the full duration The 20 hours rechar ge occurs also if a new battery is connected or the module exits the rest mode condition The following automatic commissioning duration test is only performed when...

Страница 13: ... CON 28002327 side by side 2 x 1 Accu LiFePO42B CON 28002319 side by side 4 x 1 Accu LiFePO44B CON 28002323 side by side 5 x 1 Accu LiFePO45B CON 28002326 EM converterLED PRO 1 2 3 h NiMH Type EM converterLED PRO 302 MH LiFePO4 50V EM converterLED PRO 303 MH LiFePO4 50V EM converterLED PRO 304 MH LiFePO4 50V Article no 89800640 89800641 89800629 Duration 1 h 2 3 h 1 h 2 3 h 1 h 2 3 h Battery charg...

Страница 14: ...per year plus 30 cycles during comissioning Max storage time 12 months at 5 C to 25 C 8 4 Accu LiFePO4 Capacity 1 5 Ah International designation IFpR 19 66 Battery voltage cell 3 2 V Cell type 18650 Case temperature range to ensure 4 years design life 5 C to 55 C 6 years design life 5 C to 45 C 8 years design life 5 C to 35 C Max short term temperature reduced life time 70 C Max number discharge c...

Страница 15: ...operation The Black Box can be read out with the masterCONFIGURATOR and deviceANALYSER via DALI and NFC In order to allow a safe detection of a battery replacement through the Black Box data recording follow the below described process Battery replacement 1 Disconnect mains 2 Disconnect battery 3 Reconnect and disconnect mains while no battery is not connected1 4 Connect new battery 5 Connect main...

Отзывы: