This instrument is a portable easy to use digital infrared 
thermometer with laser sighting designed for simple one 
hand operation

Features include a backlit LCD screen, Automatic HOLD and 
POWER OFF and custom made storage holster and screen 
protector

Specifications

Safety Information

•  It is recommended to read and follow these safety 

instructions prior to using the infrared thermometer

•  Pressing the trigger turns the laser beam ON and 

OFF. Exercise extreme care and do not allow the laser 
beam to shine directly into the eye of yourself or other 
individual

•  Do not look directly into the laser light from the 

optical system

•  If measuring the temperature of an object with 

a mirror finish, be careful not to allow the laser 
beam to be reflected off the surface into the eye

•  Do not allow the laser beam to impinge upon any 

gas which can explode

General Specifications 

 

Display

4 Digit Liquid Crystal Display (LCD). Max. reading of 1999

Low Battery Indication

 logo is displayed when the battery voltage drops below the 

operating level

Measurement Range

0.25 seconds, nominal

Operating Environment

0°C to 50°C (32°F to 122°F) at < 70% R.H.

Storage Temperature

-20°C to 60°C (-4°F to 140°F), 0 to 80% R.H. with battery removed 
from unit

Auto Power Off

10 seconds

Standby Consuming 
Current

< 5µa

Battery

Standard 9V (NEDA 1604, IEC 6F22006P)

Battery Life

9 hours (continuity with laser and backlight)

Dimensions

148H x 105W x 42D (mm)

Weight

Approx. 157g (inc. bat.)

Laser Specifications (Class 2 Laser)

Wave Length

Red (630-670mm)

Power Out

<1mW, class 2 laser product

Electrical Specifications

Temperature Range

-30°C to 550°C (-22°F to 1022°F)

Display Resolution

0.5/1°C (Auto), 1°F

Accuracy

+/- 2°C/4°F for -30°C to 100°C (-22°F to 212°F)
+/- 2% reading for 101°C to 550°C (213°F to 1022°F)

Temperature Coefficient

+/- 2% reading or +/-0.2°C (0.36°F) whichever is greater, change in 
accuracy per °C/°F change in ambient operating temperature above 
28°C (82.4°F) or below 18°C (64.4°F)   

Response Time

0.25 seconds

Spectral Response

6 to 14 µm

Fixed Emissivity (c)

0.95

Detection Element

Thermopile

Optical Lens

Fresnel Lens

Sighting

1 beam laser marker <1mW (class 2)

Field of View

Ø 100mm at 1000mm 

• Do not use the unit near any device which 

generates strong electromagnetic radiation 
or near a static electrical charge, as they 
may cause errors

• Do not use the unit where it may be 

exposed to corrosive or explosive gases

• Do not keep or use this init in an 

environment where it will be directly 
illuminated by sunshine or where it will 
be exposed to high temperatures, high 
humidity or condensation. If subjected 
to any of these conditions the unit may 
become damaged or function according to 
specification

• Do not point the lens at the sun or at any 

other source of strong light. This may 
cause damage to the sensor

• Do not contact the lens against the object 

to be measured, allow it to become dirty or 

scratched, or allow any foreign matter to 
adhere to it

• Do not touch or hold the unit by the front 

case. Temperature readings can be 
affected by heat from the hand

• Do not place the meter on or around 

hot objects (70°C/158°F). It may cause 
damage to the case.

• If the meter is exposed to significant 

changes in ambient temperature allow an 
extra 20 mins for temperature stabilisation 
before taking measurements

• Condensation may form on the lens when 

moving from a cold to hot environment. 
If this occurs allow 10 mins for the 
condensation to dissipate

• This is not a water proof or dust proof unit, 

therefore take precautions where using 
this unit

CAUTION