Communication
TCD Electronics | Function Manual | Version: TCD_PROFI_S_EN_200326_E003
45
3.8.18.
Dosing block, Slot 15
Index Parameter name
Data type
[size]
Access Annotation
16
BLOCK_OBJECT
DS-32
Read
only
Constant block information
17
CURRENT_MODE
Unsigned8
Read
only
Fixed to automatic (8)
18
BATCH_STATE
Unsigned8
Read
only
0: batch stopped
1: batch running
2: batch paused
3: cleaning (all valves are set to "open valve")
19
BATCH_COM-
MAND
Unsigned8
Read
Write
Used to control a dosing cycle:
1: start batch
2: stop batch
3: pause batch
4: resume batch
5: start cleaning
Reading this parameter returns 0
20
MODE
Unsigned8
Read
Write
Batching Mode
0: off, batching disabled
1: 1-stage batching
2: 2-stage batching
3: analog batching
21
INPUT_SELECTOR
Unsigned8
Read
Write
Batch input selection:
0: Mass Flow
1: Volume Flow
4: Standard Volume Flow
5: Fraction Flow Media A
6: Fraction Flow Media B
22
AMOUNT_DONE
DS-101
Read
only
Current amount that is totalized since the start of the
batch cycle. Includes a quality code
23
AMOUNT_RE-
MAINING
DS-101
Read
only
Amount that is missing to complete the current
batch
24
RECIPE_ID
Unsigned8
Read
Write
Active recipe that specifies the used parameter set.
Valid range
1…5
25
RECIPE_NAME
Visible
String(16)
Read
Write
The recipe´s name
26
RECIPE_TARGET
AMOUNT
Float32
Read
Write
The recipe´s target amount. Follows the unit setting
by
RECIPE_TAR‐
GET_AMOUNT
27
RECIPE AMOUNT
UNIT
Unsigned16 Read
Write
Unit code that influences the AMOUNT_DONE,
AMOUNT_REMAINING and RECIPE_TARGET_
AMOUNT values
28
—
—
—
—
29
RECIPE_FIXED_
COMPENSTATION
Float32
Read
Write
Define the fixed pre-stop value. The value is
subtracted from 'Amount' to compensate for
application delays in closing the valves.
Analog dosing
30
ANALOG_OUTPUT
DS-101
Read
only
Calculated set point for analog valve