- 33 -
CCS-2 1002
o
utPut
data
r ate
This menu shows the output data rate defined using the COFDM settings and
the current output data rate.
Bx 4A
31667
(28352)
STUFFING
Zahl 1
Zahl 2
Number 1 Number 2
(28352):
The current needed net output data rate.
31667:
Maximum net output data rate (dependent on the settings of modula-
tion code rate and guard interval).
If the station filter is set correctly, the current needed data rate is lower than
the maximum data rate. The value fluctuates, since the data rates of individual
stations are dynamically modified by the broadcasters.
—> Is the current needed data rate higher than the maximum data
rate question marks "
??
" appear in the display. In this case correct
the COFDM settings (pages 30 …) or the settings of the station filter
(page 24).
Bx 4A
31667
(36906) ??
STUFFING
• Press the
button.
—> The "Setting a substitute signal in the case of an incorrect input
signal" – "
FAILURE