© Copyright 2019 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
Industrial Managed Switch Series
24
New Time
Enter the new date in year, month and day format and time in
hour, minute and second format. The new date and time then
appear in the Current Date and Current Time fields after you click
Apply.
Enable
Network Time
Protocol
Select this option to use Network Time Protocol (NTP) for the time
service.
NTP Server
Select a pre-designated time server or type the IP address or type
the domain name of your time server. The Switch searches for the
timeserver for up to 60 seconds.
Time Zone
Select the time difference between UTC (Universal Time
Coordinated, formerly known as GMT, Greenwich Mean Time)
and your time zone from the drop-down list box.
Daylight Saving Settings
State
Select Enable if you want to use Daylight Saving Time. Otherwise,
select Disable to turn it off.
Start Date
Configure the day and time when Daylight Saving Time starts if you
enabled Daylight Saving Time. The time is displayed in the 24 hour
format. Here are a couple of examples:
Daylight Saving Time starts in most parts of the United States on
the second Sunday of March. Each time zone in the United States
starts using Daylight Saving Time at 2 A.M. local time. So in the
United States you would select Second, Sunday, March and 2:00.
Daylight Saving Time starts in the European Union on the last
Sunday of March. All of the time zones in the European Union start
using Daylight Saving Time at the same moment (1 A.M. GMT or
UTC). So in the European Union you would select Last, Sunday,
March and the last field depends on your time zone. In Germany
for instance, you would select 2:00 because Germany's time zone
is one hour ahead of GMT or UTC (GMT+1).
End Date
Configure the day and time when Daylight Saving Time ends if you
enabled Daylight Saving Time. The time field uses the 24 hour
format.
Here are a couple of examples:
Daylight Saving Time ends in the United States on the last Sunday
of October. Each time zone in the United States stops using
Daylight Saving Time at 2 A.M. local time. So in the United States
you would select First, Sunday, November and 2:00.
Daylight Saving Time ends in the European Union on the last
Sunday of October. All of the time zones in the European Union
stop using Daylight Saving Time at the same moment (1 A.M. GMT
or UTC). So in the European Union you would select Last, Sunday,
October and the last field depends on your time zone. In Germany
for instance, you would select 2:00 because Germany's time zone
is one hour ahead of GMT or UTC (GMT+1).
Apply
Click Apply to take effect the settings.
Refresh
Click Refresh to begin configuring this screen afresh.
Management Host
The feature limits the hosts which can manage the Switch. That is, any hosts can manage
the Switch via telnet or web browser. If user has configured one or more management
host, the Switch can be managed by these hosts only. The feature allow user to configure
management IP up to 3 entries.
Default Settings
The default is none, any host can manage the Switch via telnet or web browser.
CLI Configuration
Node
Command
Description
enable
show interface eth0
The command displays the all of the interface
eth0 configurations.
eth0
show
The command displays the all of the interface
eth0 configurations.