ZPHA Installation Guide 

7

The following image shows the blank faceplate segment module.

Figure 2-7 

Blank faceplate segment module

The following image shows the nonstandard USB-type ports located on the modular ZPHA device 
back panel.

Figure 2-8 

USB ports back panel

Full reboot and power cycle

Before you perform a 

reboot - full

 or a power cycle on your IPS or TPS device, disconnect the 

nonstandard USB power cable between the ZPHA device and the IPS/TPS device. 

WARNING!  If the ZPHA device nonstandard USB power cable is connected to the IPS/TPS 
device during a 

reboot - full

 or a power cycle, the ZPHA device continues to route network 

traffic to the device, and the IPS/TPS device blocks the traffic until the reboot sequence 
completes.

After the reboot sequence completes, reconnect the nonstandard USB power cable to enable the 
ZPHA device to route traffic back through the IPS or TPS device.

ZPHA device installation

When you install the ZPHA device, you need the following components:

To power the ZPHA device, use the nonstandard USB cable to connect the ZPHA device to the 
IPS or TPS device (once cable included). 

For copper ZPHA device segments, use RJ-45 copper network cables — four (4) per segment 
(cables not included). 

For fiber ZPHA device segments, use duplex multi-mode fiber cables — four (4) per segment 
(cables not included). The ZPHA, IPS, and TPS devices all use LC-LC type connections. 

Содержание TippingPoint ZPHA

Страница 1: ...Part Number APEM07687 170111 TippingPoint Zero Power High Availability Installation Guide Modular and Non modular...

Страница 2: ...m collects and provides detailed instructions on how to disable the specific features that feedback the information Legal Notice Copyright 2018 Trend Micro Incorporated All rights reserved Trend Micro...

Страница 3: ...e located on the front or the back of the device The ZPHA device does not require any other type of power connection to function System grounding requirements Damage from Electromagnetic Static Discha...

Страница 4: ...PHA system complete the following steps 1 Inspect the packing container If you see any damage or other signs of mishandling inform both the local freight provider and TippingPoint before unpacking You...

Страница 5: ...ot inspected or blocked This section includes the following topics ZPHA device hardware overview on page 3 ZPHA device installation on page 7 Crossover cable installation on page 13 ZPHA device hardwa...

Страница 6: ...A device includes one type A and one type B USB port while the non modular ZPHA device includes two type B USB ports You can connect the IPS or TPS device to the ZPHA device through the A or B USB typ...

Страница 7: ...n take longer to establish the link As a best practice record the required link times of the network equipment connected to the ZPHA device Use this data to tune your network switching configurations...

Страница 8: ...ows the fiber segment modules Figure 2 5 Fiber segment modules 1 Zero Power HA Fiber Segment Module 2 Zero Power HA v2 Fiber Segment Module The following image shows the copper segment module Figure 2...

Страница 9: ...the ZPHA device continues to route network traffic to the device and the IPS TPS device blocks the traffic until the reboot sequence completes After the reboot sequence completes reconnect the nonstan...

Страница 10: ...The vertical hole spacing on the rack rails must meet standard EIA 310 C requirements which call for one inch 2 54 cm spacing 2 After installing the system case place a segment module into a segment...

Страница 11: ...e network traffic through the ZPHA device to the IPS TPS device Connect a cable from port A of the IPS TPS device to port A of the ZPHA device segment Connect a cable from port B of the IPS TPS device...

Страница 12: ...e and that traffic is passing through the ZPHA device If traffic is not passing you might need to use a crossover cable instead of a straight cable for one of the network connections See Crossover cab...

Страница 13: ...rd 19 or 23 inch rack The vertical hole spacing on the rack rails must meet standard EIA 310 C requirements which call for a one inch 2 54 cm spacing 2 Connect the RJ 45 copper cables to route network...

Страница 14: ...in configuration Use a daisy chain configuration to connect multiple ZPHA devices to a single IPS or TPS device A daisy chain setup might be necessary if you need ZPHA device protection for more than...

Страница 15: ...k devices connected to the ZPHA device are not auto MDIX enabled you might still need to use a crossover cable in your configuration The following figures display different installations of the ZPHA d...

Страница 16: ...k configuration For example if the network devices connected to the ZPHA device are both DTE devices or both DCE devices use a crossover cable to connect one of the network devices to the ZPHA device...

Отзывы: