10
Ensure that any small device connected to the USB port is compatible with 5V/ 500mA
operation.
VI.Manipulating of battery protector (Low voltage protection)
-While the battery’s voltage drops to the set-up data, compressor will stop working, so as
to protect the battery against over discharge; once the battery’s voltage reaches the
restart data after charging, compressor will start immediately.
-While the battery’s voltage is too low, battery protector will take effect. Red
malfunction indicator light will blink. Now you need to charge the battery.
-While the battery protector cut off the battery connection, you should warrant the
battery to be charged sufficiently, so as avoid frequent restarting of compressor.
Voltage range of battery protector:
Power Supply
Status Battery protector
Low Mode
Medium Mode
High Mode
DC 12V
Cutting-off Voltage
10.1
±
0.3V
11.4
±
0.3V
11.8
±
0.3V
Restarting Voltage
11.1
±
0.3V
12.2
±
0.3V
12.6
±
0.3V
DC 24V
Cutting-off Voltage
21.5
±
0.3V
24.1
±
0.3V
24.6
±
0.3V
Restarting Voltage
23.0
±
0.3V
25.3
±
0.3V
26.2
±
0.3V
When the
ICERHINO freezer
is supplied by the auto starter battery, V
H
mode
setting is proposed, so as to warrant that vehicle’s battery power is in high level.
If you use additional battery for power supply, V
L
mode setting is applicable.
-
ICERHINO freezer
is designed to have the function to rework when connect to
power after power off. If the
ICERHINO freezer
is shutdown under abnormal situation, it
will work automatically when connect to power again.
VII.Defrosting
Humidity can form frost in the interior of the cooling device or on the evaporator. This
reduces the cooling capacity. Defrost the device in good time to avoid this.
Defrosting steps are as below:
-Take the stored material from the
ICERHINO freezer
.
-If it is necessary, the stored material could be stored in another
ICERHINO freezer
.
-Cut off the power, open the
ICERHINO freezer
’s lid, and keep it open until the ice and
frost melt away.