41
noticed, depending on the length of cut. The new calibration factor will flash on the
screen momentarily.
•
To cut another piece, simply press enter. Repeat the process until the desired
calibration factor is achieved.
Note: If using method 2, the calibration factor can be changed by many increments at
once. For example, if the part cut was too short, the
“
1
”
key can be pressed as many times
as desired to increase the calibration factor before making another cut.
Once the desired calibration factor has been determined for the part being cut, it is
recommended to note this factor. Older TRC 1000 machines were not equipped with
nonvolatile memory; therefore, once the machine is powered off, the calibration factor will
reset. If the calibration factor was noted, it can be reprogrammed upon starting the
machine. Newer circuit boards (Version 2.4 and up) can have nonvolatile memory added
so calibration factors will be saved even after the machine is shut off, and will resume at
the last programmed calibration factor once powered up again.
Replacing Main Fuse
On standard cutters there are two fuses. One of these fuses is located on the back of the
control panel, and one of these fuses is on the circuit board. Depending on the age of the
control panel, there will be one of two different types of fuse holders.
Type 1
The first and most common type has the main fuse located in a tray under the power
receptacle.
Figure 24: Location of fuse tray under power receptacle.