Finalizing the Installation
25
© Travis Industries
4120309
100-01287_000
5. Install the logs.
6. Replace the glass.
7. Start the heater.
8. Leak test all gas joints.
9. Check the air shutter following the directions below.
Air Shutter Adjustment
Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be
yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
10. Attach the face following the directions included with the face.
11. Adjust the flame to its highest position - the flames should not contact the top of the firebox. Check
the flame on low position. The flames should burn off of each burner hole. If the heater does not
work correctly, contact your Travis dealer for a remedy.
12. Give this manual to the home owner for future reference and fully explain operation of this heater.
Correct
Flames should be blue at the
base, yellow-orange on the top.
If the flames are too tall or sooty on the
ends, open the air shutter.
Not Enough Air
If the flames are all blue and
short, close the air shutter.
Too Much Air
Swing the control cover down to
access the air shutters.
Front Burner Air Shutter Control
(RED)
Left = Less Air
Right = More Air
Rear Burner Air Shutter Control
(GOLD)
Left = Less Air
Right = More Air