56
Finalizing the Installation
(for qualified installers only)
© Travis Industries
4090501
100-01226_000
4
Install the LP pilot orifice following the directions below.
(a) Use a 7/16” open-end wrench to remove the pilot hood.
(b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly
then replace the pilot hood, tightening the pilot hood until it is snug (do not over-tighten).
a
b
7/16" Wrench
Natural Gas Orifice = .020N (3way)
.018N (2way)
LP (Propane) Orifce = .014LP
.020N
or
.018N
.014LP
5
Replace the firebox components.
Install the logs and embers.
Replace the glass.
6
Remove and discard the screws (see “a” below) holding the stock regulator in place (see “b” below).
Remove the stock regulator and gasket (see “c” below). Place the LP regulator in place, making
sure the pre-fitted gasket (see”c” below) is in place. NOTE: There is a label on the base of the
regulator knob indicating regulator type (NG or LP). Secure the regulator with the screws included
with the regulator – tighten to 25 lb-in of torque (2.82 NM). Place the included label on the valve body
where it can be easily seen to insure proper identification.
NOTE: Leak test this area after the
heater is installed, gas is connected, and the main burner is lit.
a
T-20 Torx or
Slotted Screwdriver
b
c
d
7
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve.