26 Installation
(for qualified installers only)
© Travis Industries
4090501
100-01226_000
Rear Vent Configuration with Horizontal Termination (no vertical rise)
•
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45° Elbow
Termination
See the charts below to
determine maximum vent
3 feet (0.915m)
0 feet
0 feet
4' max (1.22m)
• Exhaust Restrictor # 1 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
Vent with No 45° Elbow
3 feet (0.915m)
0 feet
0 feet
2' max (0.61m)
Vent with 1 45° Elbow
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal
Section(s)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1219mm) Horizontal
Section(s)
• Exhaust Restrictor # 1 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)