Traulsen RMC Series Скачать руководство пользователя страница 1

INITIAL START DATE: 

 

 

 

SERIAL NO.           

 

MODEL 

TYPE: 

         

COMPANY/INDIVIDUAL 

NAME: 

        

INSTALLER:            

This Traulsen unit is built to our highest quality standards.  We build our refrigerators and freezers this way as a matter of 

pride.  This philosophy has made Traulsen the leader in commercial refrigeration since 1938.  We thank you for your choice and 

confidence in Traulsen equipment and we know you will receive many years of utility from this equipment.

All Traulsen units are placed on a permanent record file with the service department.  In the event of any future questions you 

may have, please refer to the model and serial number found on the name tag affixed to the unit.  Should you need service, call 

us on our toll free number, 800-825-8220 between 7:30 am - 4:30 pm CST, Monday thru Friday.  You may also log onto www.

traulsen.com for further information.  It is our pleasure to help and assist you in every possible way.

OWNER’S MANUAL

Instructions for the installation, operation

 and maintenance of Traulsen:

             FORM NUMBER TR35944 (REV. 10-01-20)   

 

 

 

 

 

 

                                      P/N 375-60324-00

Quality Refrigeration

INSTALLER

COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION

RMC Milk Cooler

RMC34, RMC49 & RMC58 Models

* For equipment produced after 10-2020 only

Содержание RMC Series

Страница 1: ...epartment In the event of any future questions you may have please refer to the model and serial number found on the name tag affixed to the unit Should you need service call us on our toll free number 800 825 8220 between 7 30 am 4 30 pm CST Monday thru Friday You may also log onto www traulsen com for further information It is our pleasure to help and assist you in every possible way OWNER S MAN...

Страница 2: ...t type used and refrigerant charge Design Pressure System 1 High and Low Pressure Refrigerant SYS2 System 2 Refrigerant type used and refrigerant charge Design Pressure System 2 High and Low Pressure Volts Voltage Hz Cycle Total Current Maximum amp draw Min Circuit Amps Minimum circuit ampacity Agency Labels Designates agency listings This unit is listed to UL 471 CSA 120 and NSF 7 by an approved ...

Страница 3: ...f at all possible we suggest that the cabinet remain bolted to the pallet dur ing all transportation to the point of final installation The bolts can then be removed with a 1 2 socket wrench Avoid laying the unit on its back for removal of the pallet NOTE Traulsen does not recommend laying the unit on its back If you must please allow the unit to remain in an upright position for 24 hours before p...

Страница 4: ...nnect electrical power to the cabinet and remove the system side cover Proceed to vacuum or brush any dirt lint or dust from the finned condenser coil filter the compressor and other cooling system parts If significant dirt is clogging the condenser fins or filter use compressed air to blow this clear To replace the system side cover reverse the process V b REPLACING THE DOOR GASKETS To remove the...

Страница 5: ...may tend to mar and scratch the surface Do NOT use cleansers containing chlorine such as bleach this may promote corrosion of the stainless steel Care should also be taken to avoid splashing the unit with water containing chlorinated cleansers when mopping the floor around the unit For stubborn odor or spills use baking soda and water mixed to a 1 tbsp baking soda to 1 pint water ratio A stainless...

Страница 6: ... 5 VI a WIRING DIAGRAM NOTE Refer to the wiring diagram below for any service work performed by a qualified technician VI WIRING DIAGRAM ...

Страница 7: ...starts automatically as soon as the time set with parameter DFT has elapsed Timed defrost With DFM TIM defrosts take place at regular intervals when the timer reaches the value of DFT For example with DFM TIM and DFT 36 a defrost will take place every 6 hours Optimized defrost With DFM FRO the timer is only increased when the conditions occur for frost to form on the evaporator until the time set ...

Страница 8: ...button and for 5 seconds With button or select the parameter to be modified Press button to display the value By keeping button pressed use button or to set the desired value When button is released the newly programmed value is stored and the following parameter is displayed To exit from the setup press button or wait for 30 seconds VII e TECHNICAL DATA Power supply TRL 002 W 100 240Vac 10 50 60H...

Страница 9: ...increase CRN defrost is based off of compressor run time time is based off of DAT DFT 0 250 Time interval among defrosts in x10 minutes When this time has elapsed since the last defrost a new defrost cycle is started Each number is multiplied by 10 minutes 0 250 indicates 0 2500 minutes DAT 0 100 hours Frost accumulation timeout DFB NO YES Defrost timer backup With DFB YES after a power interrupti...

Страница 10: ... stop in x10 seconds With FT2 0 the fans remain on all the time FT3 0 180 Timed fan run in x10 seconds With FT3 0 and FT2 0 the fans remain off all the time ATM NON ABS REL Alarm threshold management NON all temperature alarms are inhibited the following parameter will be ACC ABS the values programmed in ALA and AHA represent the real alarm thresholds REL the alarm threshold is obtained by the sum...

Страница 11: ...er door has been opened D1O NON DOR ALR IISM RDS DI1 digital input operation NON digital input 1 not active DOR door input ALR when the input is on an alarm is generated if AHM STP the compressor is stopped and the defrosts are suspended IISM when the input is on the controller will use group 2 parameters RDS when the input is on a defrost is started remote control D1A OPN CLS DI1 digital input ac...

Страница 12: ...measurement 2EU second evaporator temperature measurement OS3 12 5 12 5 Probe 3 offset AHM NON ALR STP Operation in case of high condenser alarm NON high condenser alarm inhibited ALR in case of alarm HC flashes in the display and the buzzer is switched on STP in addition to the alarm symbols displayed the compressor is stopped and defrosts are suspended AHT 50 110 Condensation temperature alarm re...

Страница 13: ...ICS continued VII f COMPONENTS AND WIRING DIAGRAM Indications Control Wiring Diagram Thermostat output Fan output Defrost output Activation of 2nd patameter set Alarm Manual activation Increase button Exit Stand by button ...

Страница 14: ...pt open for a long period of time in both cases allow adequate time for the cabinet to recover its normal operating temperature c Control setting too high readjust per instructions on section VII b d Check that condensing coil is clean 4 Food compartment is too cold a Perhaps a large quantity of very cold or frozen food has recently been added Allow adequate time for the cabinet to recover its nor...

Страница 15: ...Alt San Other 2 Symbol 3 Alt En Other 3 Symbol 4 WEEE Symbol 5 Safety Symbol 6 Sanitation Symbol 7 Energy Symbol 8 Customer QR Code Other 4 Device Part Number PartNum UL NSF Notes SCAN FOR SERVICE INFO COMPONENTS COMPOSANTS COMPONENTES COMP AMPS EVAP FAN AMPS COND FAN AMPS LIGHT WATTS DEF HTR AMPS CTRL AMPS DOOR HTR AMPS MIN AMPS MAX AMPS 370 60297 00 REV A 11 20 14 4401 Blue Mound Rd Ft Worth TX ...

Страница 16: ...d parties Additionally the Equipment is intended only for commercial use and should not be used by consumers or households or in any non commercial application This Domestic Warranty does not apply to and shall not cover any Equipment that is installed or used in any way in any residential or non commercial application No warranties express or implied are provided to any residential consumer or no...

Страница 17: ... 16 NOTES ...

Страница 18: ... OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2020 Traulsen All Rights Reserved Traulsen 4401 Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax 817 740 6757 traulsen com ...

Отзывы: