Transmitter Solutions Reign XRE-100 Скачать руководство пользователя страница 1

WHAT’S INCLUDED

 

The REIGN XRE-100 Relay Extender is a revolutionary product that 

will make any dry contact wireless with no programming or 

configuration whatsoever - it literally is a plug and play device.

HOW IT WORKS...

 

Congratulations on your purchase of the Transmitter Solutions XRE-100 Relay Extender System.  It has been 
designed with state-of-the-art radio technology to extend relay closures, switches, indicators, sensors, and any 
other simple ON/OFF status inputs and outputs up to 40 miles line-of-sight. 

 
If you ordered your XRE-100s together, they are factory paired.  All that is required to get up and running is 12-24 
Volts AC/DC power and the DRY input closures you want to extend. 

 
If you would like to survey the range capability before install, simply provide power to both units and press the 
PROG/TEST button alternately on each unit.  Successful transmission and reception will be indicated on the 
transmit and receive LEDs on each unit as described below.

v.8.29.18

X R E

1 0 0

RELAY EXTENDER

There are two pieces that complete the XRE-100.

 
The Reign XRE-100 - Relay Extender kit includes 2- XRE-100 units. These units are interchangeable and can be 
paired in the field.

 
Transmitter Solutions refers to the XRE-100 installed at the peripheral device as the Node and the XRE-100 
installed at the primary unit the Hub. This is only important during technical support and the wiring diagram.

R E I G N   w i r e l e s s

t e c h n o l o g y

Содержание Reign XRE-100

Страница 1: ...2 24 Volts AC DC power and the DRY input closures you want to extend If you would like to survey the range capability before install simply provide power to both units and press the PROG TEST button alternately on each unit Successful transmission and reception will be indicated on the transmit and receive LEDs on each unit as described below v 8 29 18 X R E 1 0 0 RELAY EXTENDER There are two piec...

Страница 2: ...2 ...

Страница 3: ...Encryption AES 1 POWER DETAILS 4 2 LED INDICATORS 5 3 RELAY DIAGRAM AND WIRING 6 4 ALERT RELAYS 7 5 DIP SWITCHES 8 6 BATTERY BACKUP 9 7 PAIRING IN THE FIELD 9 TROUBLESHOOTING 1 0 POWER INPUT 12 to 24 VOLTS AC DC 1 AMP Minimum Always follow polarity when DC Power is used BATTERY INPUT for 12 Volt Sealed Lead Acid SLA battery only Solid GREEN LED indicates battery charging Momentarily flashing GREEN...

Страница 4: ...AST 1AMP POWER SUPPLY POWER INPUT Power Input 12 to 24 VOLTS AC DC Always follow polarity when DC Power is used 1 AMP Minimum BATTERY INPUT Battery Input for 12 Volt Sealed Lead Acid SLA battery only Solid Green LED Battery charging Momentary Flashing LED Battery is fully charged and a trickle conditioning charge is occurring 1 2 2 1 4 ...

Страница 5: ... result of an Relay Input change event or handshake STATUS PROG flashes yellow patterns indicating status of the unit pairing error etc RUN flashes ORANGE 1 second ON and 1 second OFF indicating the microprocessor is running POWER LED Glows solid orange when power is present 5 volt relay supply 3 3 volt logic supply and VPA 3 6 volt power amplifier supply 1 3 1 2 3 4 5 4 2 5 5 ...

Страница 6: ...XRE 100 A closure on RLY2 COM input will result in a closure on RLY2 NC COM NO output of the paired XRE 100 RELAY OUTPUTS Relay Outputs The Reign XRE 100 comes with 2 relay outputs Each output follows RELAY INPUTS from remote paired XRE 100 When RLY1 or RLY2 INPUTS are closed RLY1 and RLY2 OUTPUTS are energized and connect NC COM NO respectively This relay state is also indicated by the GREEN ACTI...

Страница 7: ...d with the supplied 3K ohm resistor Simply insert the resistor into the Rx and COM pins on the desired connector and tighten screw blocks If Supervised Inputs are not desired simply leave DIPSWITCH 2 OFF and wire your contact directly across the Rx and COM pins NOTE Communication Loss If the XRE 100 units stop communicating the Alert Relay Output Black relay will trigger Alerting on loss of commun...

Страница 8: ...n XRE 100 to XRE 100 Relay Extension operation PROGRAM TEST BUTTON Program Test Button used with MODE SWITCH 1 to field pair units as described above Functions as a TEST TRANSMIT button during normal operation When pressed the XRE 100 will send a radio test packet and the RED TRANSMIT LED will illuminate If the paired XRE 100 is online it will acknowledge with a radio test packet indicated by a mo...

Страница 9: ...1 to ON on both units Press the PROG TEST button on either unit NOTE Observe the STATUS PROG LED flashing Flip Dipswitch 1 to OFF on both units Press PROG TEST and observe TRANSMIT and RECEIVE LEDs operating normally Pairing procedure overwrites any previous units For example if replacing a unit simply follow the above procedure with the existing and replacement unit 7 PAIRING UNIT IN THE FIELD 1 ...

Страница 10: ...tary on the green receive LED If you do not see the transmit and receive LED lights activate 1 Power cycle both the XRE units 2 Move the XRE 100 units to a higher location and avoid mounting on in metal objects If you are not getting the desired range between XRE 100 units 1 Ensure that the both devices are powered by their own dedicated power supply 2 Ensure that 1 amp of power draw is available ...

Страница 11: ...YER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND WHETHER DIRECT INCIDE...

Страница 12: ...PH 866 975 0101 FX 866 975 0404 www transmittersolutions com ...

Отзывы: