background image

COMPLIANCE INFORMATION

UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.  This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.  Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables

aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.

European Regulations

Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen
werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques
appropriées

Trademark Notice

All registered trademarks and trademarks are the property of their respective owners.

Copyright Restrictions

© 1999 TRANSITION Networks.
All rights reserved.  No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A.

33121.A

The TRANSITION Networks rack-mountable PowerStar

V, PSV-2/14-45,

converts a twinax daisy-chain topology to an unshielded twisted-pair star
topology in AS/400™, Sys36, or 5x94 remote controller host
environments. The PowerStar

V supports all 5250 compliant devices

operating at speeds of either 1 Mb/s OR 2 Mb/s (IBM

®

5250 Express*). 

PSV-2/14-45

The PowerStar™ V distributes one or two host input signals from the
AS/400, Sys36, or 5x94 remote controller, received over twinax, fiber, or
twisted-pair media, to up to seven (7) terminal devices for each host input
signal (up to fourteen (14) terminal devices for two host input signals). 

All signals from the PowerStar™ V to terminal devices are over twisted-
pair using RJ-45 port connectors.

PS-T-SIC  Optional slide-in-card (SIC) for the TRANSITION Networks
PowerStar

V; when installed, provides two (2) twinax link connections for

host input signal(s).

PS-F-SIC  Optional slide-in-card (SIC) for the TRANSITION Networks
PowerStar

V; when installed, provides two (2) fiber link connections for host

input signal(s).

*Refer to IBM

®

5250 Express reference

material available from network
vendors when installing PowerStar™ V
in a 5250 Express network.

Minneapolis, MN  55344  USA

PowerStar

V

1-2 Mb/s Hub for AS400

, S3/x , 5x94 Host

PSV-2/14-45

USER’S GUIDE

PSV-2-14/45 in the Network . . . . . . .2
Installation  . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . .12
Cable Specifications  . . . . . . . . . . . .13
Technical Specifications  . . . . . . . . .15
Compliance Information . . . . . . . . .16

1

2

3

4

5

6

0

1

2

3

4

5

6

0

Left Link 

Parity Error 

Line Sync 

CAUTION:  RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 

Содержание PSV-2/14-45

Страница 1: ...s All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S...

Страница 2: ...stalled in the PowerStar V and a compatible twisted pair fiber media converter such as the TRANSITION Networks IBM 5250 is available the link from the host to the PowerStar V can be made by installing...

Страница 3: ...ometers 10 000 feet Actual distance dependent upon physical characteristics of network installation ST CONNECTOR AS 400 S 3x or 5x94 up to 762 meters 1 Multimode up to 2 kilometers Singlemode up to 8...

Страница 4: ...slide in card thumbscrews into PowerStar V threaded holes CABLE SPECIFICATIONS Twisted Pair Cable and Connector Specifications Category 3 OR BETTER twisted pair copper wire is required Either shielded...

Страница 5: ...al shock WARNING AVOID CONTACT WITH POWER SUPPLY during jumper pin setting Failure to observe this warning could result in personal injury or death from electrical shock caused by capacitive discharge...

Страница 6: ...wer ON the PowerStar V 1 At PowerStar V back locate the power receptacle and associated fuse 2 Verify that fuse is installed at correct rating setting for power source voltage The installed fuse ratin...

Страница 7: ...g the site installation handle the PSV 2 14 45 in such a way that the PSV 2 14 45 does not fall Failure to observe this warning could result in injury to personnel and or equipment damage NOTE If PSV...

Страница 8: ...to AS 400 Sys 36 or 5x94 controller port 4 Connect other end of twinax cable to twinax port connector on slide in card 5 Optionally connect second twinax cable to second twinax port connector on twina...

Отзывы: