ION Power Supply Interoperability
The table below shows ION power supply module interoperability. In the table below, where
IONPS-x-R1
is referenced,
the
x
indicates
A
or
D
(IONPS-A-R1 or IONPS-D-R1).
#
PS #1 (Slot #22)
PS #2 (Slot #23)
Notes
1
IONPS-x-R1 (Primary)
(empty)
VALID
2
IONPS-x-R1 (Secondary)
(empty)
VALID
3
(empty)
IONPS-x-R1 (Primary)
VALID
4
(empty)
IONPS-x-R1 (Secondary)
VALID
5
IONPS-x-R1 (Primary)
IONPS-x-R1 (Primary)
VALID
6
IONPS-x-R1 (Primary)
IONPS-x-R1 (Secondary)
VALID
7
IONPS-x-R1 (Secondary)
IONPS-x-R1 (Secondary)
INVALID
8
IONPS-A
IONPS-x-R1 (Primary)
VALID
9
IONPS-A
IONPS-x-R1 (Secondary)
VALID
10 IONPS-x-R1 (Primary)
IONPS-A
VALID
11 IONPS-x-R1 (Secondary)
IONPS-A
INVALID
12 IONPS-D
IONPS-x-R1 (Primary)
VALID
13 IONPS-D
IONPS-x-R1 (Secondary)
VALID
14 IONPS-x-R1 (Primary)
IONPS-D
VALID
15 IONPS-x-R1 (Secondary)
IONPS-D
INVALID
IONPS-x-R1 Primary/Secondary functionality is user configurable, and works in all scenarios (
except where
both supplies are set to
Secondary).
IONPS-A and IONPS-D Primary/Secondary functionality is determined by which slot the Power Supply is
installed in Slot 22 (PS1) = Primary, Slot 23 (PS2) = Secondary.
IONPS-x-R1 can be manually configured to Load Share (default, Primary/Primary).
Minimum Firmware/Software Versions Required
:
IONMM FW v 1.3.1815 for IONPS-D-R1
IONPS-D-R1 v 1.2.5
FocalPoint v 3.1.2.0