![Transition Networks E-TBT-MC05 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/transition-networks/e-tbt-mc05/e-tbt-mc05_user-manual_1152296004.webp)
Transition Networks
E-TBT-MC05 10Base-T Transceiver User Guide
33406 Rev. C
Page
4
of
14
Connectors and Cables
AUI Male Connector
AUI D-sub 15-pin male connector accommodates AUI drop cables (50 meters max.). The AUI connector is used to
connect the transceiver to the AUI port of an Ethernet device such as an Ethernet MAC controller, a repeater, or
a hub via an AUI drop cable.
The AUI connector is shown in Figure 4. The AUI male connector pin assignments are show in Table 1.
Figure 4: E-TBT-MC05 AUI Male Connector Pin Assignments
Table 1: AUI Male Connector Pinouts
Pin
Name
Pairs
Use
3
DO+
Transmit
Data Out +
10
DO-
Pair
Data Out -
11
DO S
Data Out Shield
5
DI +
Receive
Data In +
12
DI -
Pair
Data In -
4
DI S
Data In Shield
7
CO +
Option
Control Out +
15
CO -
Pair
Control Out -
8
CO S
Control Shield
2
CI +
Collision
Control In +
9
CI -
Pair
Control In -
1
CI S
Control Shield
6
VC
Power
Voltage Common
13
VP
Pair
Voltage Plus
14
Vs
Voltage Shield