Transition Networks CRS4Fxxxx-10x Скачать руководство пользователя страница 1

USER’S GUIDE

CRS4Fxxxx-10x

Slide-in-Module Media
Converter

RS485/422 Copper to Fiber 

Transition Networks CRS4Fxxxx-
10x series media converters are
designed to be installed in the

PointSystem™

chassis and connect

RS485/422 copper cable to fiber-
optic cable at asynchronous data

rates up to 1.25 Mb/s. 

The CRS4F31xx-10x media converters use a male DB-9 port for the copper link: 

The CRS4F32xx-10x media converters use a 6-position terminal block for the copper

link: 

*

Maximum cable distance is 1200m 

(4000 ft)

@ <90 kb/s decreasing logarithmically to
92m

(300 ft)

@ 500 kb/s.

**Typical maximum cable distance.  Actual

distance is dependent upon the physical
characteristics of the network installation.

Installation  . . . . . . . . . . . . . . . . . . . . .3
Operation  . . . . . . . . . . . . . . . . . . . . .8
Cable Specifications . . . . . . . . . . . . . .9
Technical Specifications . . . . . . . . . .12
Troubleshooting  . . . . . . . . . . . . . . .13
Contact Us  . . . . . . . . . . . . . . . . . . .14
Compliance Information  . . . . . . . . .15

Part Number

Port One - Copper
DB-9 port

Port Two - Fiber-Optic

CRS4F3111-100

RS485/422
1200 m

(4000 ft)*

ST, 1300 nm multimode
2 km 

(1.2 miles)**

CRS4F3113-100

RS485/422
1200 m

(4000 ft)*

SC, 1300 nm multimode
2 km 

(1.2 miles)**

CRS4F3114-100

RS485/422
1200 m

(4000 ft)*

SC, 1310 nm single mode
20 km 

(12.4 miles)**

CRS4F3115-100

RS485/422
1200 m

(4000 ft)*

SC, 1310 nm single mode
40 km 

(24.8 miles)**

Part Number

Port One - Copper
6-position terminal block

Port Two - Fiber-Optic

CRS4F3211-100

RS485/422
1200 m

(4000 ft)*

ST, 1300 nm multimode
2 km 

(1.2 miles)**

CRS4F3213-100

RS485/422
1200 m

(4000 ft)*

SC, 1300 nm multimode
2 km 

(1.2 miles)**

CRS4F3214-100

RS485/422
1200 m

(4000 ft)*

SC, 1310 nm single mode
20 km

(12.4 miles)**

CRS4F3215-100

RS485/422
1200 m

(4000 ft)*

SC, 1310 nm single mode
40 km

(24.8 miles)**

CRS4F31xx-10x

CRS4F32xx-10x

Содержание CRS4Fxxxx-10x

Страница 1: ...eration 8 Cable Specifications 9 Technical Specifications 12 Troubleshooting 13 Contact Us 14 Compliance Information 15 Part Number Port One Copper DB 9 port Port Two Fiber Optic CRS4F3111 100 RS485 4...

Страница 2: ...ysical characteristics of the network installation techsupport transition com Click the Transition Now link for a live Web chat 3 Installation CAUTION Wear a grounding device and observe electrostatic...

Страница 3: ...nstallation Continued Install the Slide In Module CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing the media converter Failure to observe this caution co...

Страница 4: ...models Note Shielded RS485 422 cables are required for EMC compliance 1 Locate or build RS485 422 cables with a female DB 9 connector on one end and a DB 9 connector that is compatible with the other...

Страница 5: ...data activity on the copper link Local switch settings Network commands cannot be entered via SNMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable...

Страница 6: ...14 100 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Link Budget 16 0 dB CRS4F3215 100 1310 nm single mode Fiber...

Страница 7: ...or power faults Copper based media ports e g Twisted Pair TP Ethernet USB RS232 RS422 RS485 DS1 DS3 Video Coax etc are NOT to be connected to inter building outside plant link segments that are subjec...

Страница 8: ...d in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interferenc...

Страница 9: ...tive owners Copyright Restrictions 2004 2010 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without...