Transition Networks CBFTF1011-155 Скачать руководство пользователя страница 1

*

Typical maximum cable distance.  Actual distance is dependent upon the physical
characteristics of the network.  (TX) = transmit   (RX) = receive

**  CBFTF1029-155 and CBFTF1029-156 are intended to be installed in the same

network where one is the local converter and the other is the remote converter.

***  CBFTF1029-157 and CBFTF1029-158

are intended to be installed in the same
network where one is the local converter
and the other is the remote converter.

User’s Guide

CBFTF10xx-15x

Slide-in-Module Media Converter

Copper to Fiber

10/100 Bridging 

(2-Port)

10Base-T/100Base-TX to 100Base-FX

The CBFTF10xx-15x 2-port Ethernet/Fast Ethernet
bridging media converter is designed to be installed in
a Transition Networks 

PointSystem™

chassis and

connects 10Base-T Ethernet or 100Base-TX Fast
Ethernet twisted-pair copper network devices to
network devices on a 100Base-FX Fast Ethernet fiber
network.

CBFTF1029-155

**

RJ-45
100 m

(328 ft)*

SC, 1310 mn (TX)/1550 nm (RX)
single mode, 20 km

(12.4 miles)*

CBFTF1029-156**

RJ-45
100 m 

(328 ft)*

SC, 1550 mn (TX)/1310 nm (RX)
single mode, 20 km 

(12.4 miles)*

CBFTF1029-157*** 

RJ-45
100 m 

(328 ft)*

SC, 1310 mn (TX)/1550 nm (RX)
single mode, 40 km 

(24.8 miles)*

CBFTF1029-158***

RJ-45
100 m 

(328 ft)*

SC, 1550 mn (TX)/1310 nm (RX)
single mode, 40 km 

(24.8 miles)*

Part Number

Port One - 

Copper

10Base-T/100Base-TX

Port Two - 

Duplex Fiber-Optic

100Base-FX

CBFTF1011-155

RJ-45
100 m 

(328 ft)*

ST, 1300 nm multimode
2 km (

1.2 miles)*

CBFTF1013-155

RJ-45
100 m

(328 ft)*

SC, 1300 nm multimode
2 km

(1.2 miles)*

CBFTF1014-155

RJ-45
100 m

(328 ft)*

SC, 1310 nm single mode
20 km

(12.4 miles)*

CBFTF1015-155

RJ-45
100 m

(328 ft)*

SC, 1310 nm single mode
40 km

(24.8 miles)*

CBFTF1018-155

RJ-45
100 m

(328 ft)*

MT-RJ, 1300 nm multimode
2 km

(1.2 miles)*

Installation  . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .5
Cable Specifications  . . . . . . . . . . .8
Technical Specifications  . . . . . . . .9
Troubleshooting  . . . . . . . . . . . . .10
Compliance Information . . . . . . .12

Содержание CBFTF1011-155

Страница 1: ...r network devices to network devices on a 100Base FX Fast Ethernet fiber network CBFTF1029 155 RJ 45 100 m 328 ft SC 1310 mn TX 1550 nm RX single mode 20 km 12 4 miles CBFTF1029 156 RJ 45 100 m 328 ft SC 1550 mn TX 1310 nm RX single mode 20 km 12 4 miles CBFTF1029 157 RJ 45 100 m 328 ft SC 1310 mn TX 1550 nm RX single mode 40 km 24 8 miles CBFTF1029 158 RJ 45 100 m 328 ft SC 1550 mn TX 1310 nm RX ...

Страница 2: ...tion Continued Set the Jumpers The jumpers are located on the media converter circuit board Use small needle nosed pliers or a similar device to set the jumper The Hardware Software jumper is labeled H for hardware and S for software Hardware The media converter mode is determined by the 4 position switch settings listed above Software The media converter mode is determined by the most recently sa...

Страница 3: ...x 15x media converter as described Connect the male TX cable connector to the female TX connector Connect the male RX cable connector to the female RX connector 3 Connect the fiber cables to the other device media converter hub etc as described Connect the male TX cable connector to the female RX connector Connect the male RX cable connector to the female TX connector Connect the fiber cable to th...

Страница 4: ...s a link partner that is in forced mode and therefore cannot participate in the auto negotiating process Parallel Detection can be set to IEEE Standard half duplex or the non standard full duplex Switch settings for parallel detection are valid in hardware or software mode only when Auto Negotiation is enabled techsupport transition com Click the Transition Now link for a live Web chat 7 Operation...

Страница 5: ... 6 are the two active pairs in an Ethernet network Use only dedicated wire pairs for the active pins e g blue white white blue orange white white orange etc Do not use flat or silver satin wire Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 1 2 3 6 1 2 3 6 1 2 3 6 techsupport transition com Click the Transition Now link for a live Web cha...

Страница 6: ... selected 100Mb s operation If the speed is not correct disconnect and reconnect the twisted pair cable to restart the initialization process Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat 11 Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 ...

Страница 7: ...uct In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Gerät der Funkstörgrenzwertklasse A In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environme...