The rear panel of the ionizer has the 24 VDC power input
connector and a grounding point.
Physically small and light.
Rapidly decays static charges.
Excellent ion balance and ionization performance.
Ionization (green) and HV alarm (red) lights.
No periodic adjustments.
Durable, replaceable tungsten alloy emitter points.
Removable front grill.
Adjustable air volume.
Power Requirements
The Model IN5120 High frequency AC benchtop air
ionizer is powered by an external DC switching power sup-
ply that operates from 100-240 VAC 50/60 Hz. The output
of the supply is +24 VDC @ 500 mA.
The IN5120 blower operates on an input of +24 VDC,
7W.
Operation and Use
Environmental Conditions
The IN5120 can be operated in areas where humidity
is 20-70% RH (Non-condensing). Excess humidity may af-
fect ionizer performance. The temperature range for the
IN5120 is 65-78°F (18-25° C).
2
Содержание Ptec IN5120
Страница 1: ...Static Eliminators Instruction Manual IN Tool Ionizer Model IN5120...
Страница 11: ...IN5120 Line Drawing 9...