14
Enter
Reader Response
What It Does
#520
PWRB Px R0
P0 = no power fail has occurred
P1 = power fail has occurred
Display power fail bit
#521
RDID xx
xx = 00–FF
Display reader ID number
#527
RFST Cx Ox T1 Fxx Rxx Gxx Axx
C0 = RF controlled by host
C1 = RF-by-input control
O0 = RF off
O1 = RF on
T1 = uniqueness timeout of 2 min
Fxx = RF output frequency, 00 to 34
Rxx = ATA RF output range, 00 to 1F
Gxx = eATA RF output range, 00 to 1F
Axx = RF power attenuation, 00 to 0A
Display RF status
#532
TOF <0 to 1>
0 = Wiegand disabled
1 = Wiegand enabled
Display Wiegand mode status
#533
WTI <01 to FF>
seconds (1-255) in hex
Display Wiegand retransmit Interval
#570
ATA:_ eGo: _ SeGo: _ IAG: _ SORT: _
I = IT500 ID (64 bits)
E = enabled
F = full transaction
D = disabled
Display tag mode status
#610
Done
Select basic protocol
#6140
Done
Disable flow control
#621
Done
Select predefined output mode
#63
Model [model]
Ver [version no.] SN [serial no.]
Copyright [date]
TransCore
Reset reader
#6400
Done
Turn RF off
#6401
Done
Turn RF on
#641
Done
Select RF-by-input control
#642NN
(00 – FF)
Done
Set RF operating frequency.
Backward compatible with
Encompass 2 and AI1620 readers.
#643NN
Done
Set operating range for ATA protocol
(distance); 00 = shortest